Loading...
5 - 28
5. DISPLAY AND OPERATION SECTIONS
m) Repeated operation status
Operation status, repeated pattern, the number of repeats in the repeated operation is displayed.
n) Close
Click the "Close" button to cancel the positioning operation mode and close the window.
(2) Status display
The status display can be monitored during positioning operation.
5.10.4 Motor-less operation
Without a servo motor being connected, the output signals are provided and the status is displayed as if the
servo motor is running in response to input device. This operation can be used to check the sequence of a
host programmable controller or the like.
(1) Operation
Turn off the servo-on (SON), and then select motor-less operation. After that, perform external operation as
in ordinary operation.
(2) Status display
The servo status can be checked in the motor-less operation.
Change the display to the status display screen by pressing the "MODE" button. (Refer to section 5.2.)
The status display screen can be changed by pressing the "UP" or the "Down" button. (Refer to section
5.3.)
(3) Termination of motor-less operation
To terminate the motor-less operation, turn the power off.