EasyManua.ls Logo

Mitsubishi Electric MELSERVO-JN Series - 11.3 Junction terminal block MR-TB26 A

Mitsubishi Electric MELSERVO-JN Series
480 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 - 25
11. OPTIONS AND PERIPHERAL EQUIPMENT
(b) MR-RB032
[Unit: mm]
6 mounting hole
TE1
30
15
Approx.20
99
1.6
119
Approx.12
14412
Approx.6156
168
6
6
5
G3
G4
P
C
TE1 terminal block
Tightening torque: 0.5 to 0.6 [N m]
Applicable wire size: 0.2 to 2.5 [mm
2
]
Mounting screw
Screw: M5
Tightening torque: 3.24 [N m] (28.7 [lb in])
(4 to 5 [lb in])
(AWG24 to AWG12)
Mass: 0.5[kg] (1.1[lb])
11.3 Junction terminal block MR-TB26A
(1) How to use the junction terminal block
Always use the junction terminal block (MR-TB26A) with the junction terminal block cable (MR-TBNATBL
M) as a set.
Use the junction terminal block by mounting it onto the DIN rail.
MR-TBNATBL M
Cable length:
05: 0.5m
1 : 1m
The terminal numbers described on the junction terminal block match the pin numbers of the servo
amplifier's CN1 connector. S in the terminal number means a shield.
Servo amplifier
Junction terminal block
MR-TB26A
Junction terminal block cable
(MR-TBNATBL M)
CN1
Ground the junction terminal block cable using the S terminal on the junction terminal block.