13 - 75
13. POSITIONING MODE
13.7.3 Extension setting parameters (No. PC
)
POINT
For any parameter whose symbol is preceded by *, set the parameter value
and switch power off once, then switch it on again to make that parameter
setting valid.
Set any parameter with [Applied] written in the name column when using an
advanced function.
Never change parameters for manufacturer setting.
(1) Parameter list
No. Symbol Name
Initial
value
Unit Reference
PC01
This parameter is not used. Do not change this value by any means.
0
PC02
0
PC03 STC
S-pattern acceleration/deceleration time constant
0 ms (2) in this section
PC04
This parameter is not used. Do not change this value by any means.
0
PC05
0
PC06
100
PC07
500
PC08
1000
PC09 MBR
Electromagnetic brake sequence output
100 ms Section 4.3.2
PC10 ZSP
Zero speed
50 r/min
PC11 *BPS
Alarm history clear
000h
PC12
This parameter is not used. Do not change this value by any means.
0
PC13 *ENRS
Encoder output pulses selection
000h Section 4.3.2
PC14 TL2
Internal torque limit 2
[Applied] 100 %
PC15 ERZL
Error excessive alarm detection level
3.0 rev
PC16
For manufacturer setting
3.0
PC17 *OSL
Overspeed alarm detection level
0 r/min Section 4.3.2
PC18
For manufacturer setting
1000
PC19
0
PC20
000h
PC21
001h
PC22 *COP1
Function selection C-1
[Applied] 000h Section 4.3.2
PC23
This parameter is not used. Do not change this value by any means.
000h
PC24 *COP3
Function selection C-3
[Applied] 000h Section 4.3.2
PC25 *COP4
Function selection C-4
[Applied] 000h
PC26 ALDT
Detailed setting of overload tough drive
[Applied] 200 ×10ms
PC27 OSCL
Detailed setting of vibration tough drive
[Applied] 50 %
PC28 CVAT
Detailed setting of instantaneous power failure tough drive
[Applied] 3 ×10ms
PC29 *COP5
Function selection C-5
[Applied] 000h
PC30
This parameter is not used. Do not change this value by any means.
000h
PC31
200
PC32
300
PC33
500
PC34
800