FLOOR-STANDING MFZ-KA
VA Series M series
OPERATION
FLOOR-
STANDING
C-266
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil from
frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
b. DRY ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button.
POWER lamp of the indoor unit turns on with a beep tone.
(2) Select DRY mode with OPERATION SELECT button.
(3) The microprocessor reads the room temperature and determines
the set temperature.
c. HEAT ( ) OPERATION
(1) Press OPERATE/STOP (ON/OFF) button.
POWER lamp of the indoor unit turns on with a beep tone.
(2) Select HEAT mode with OPERATION SELECT button.
(3) Press
TEMPERATURE buttons (TOO WARM or TOO COOL button) to select the desired temperature.
The setting range is 16 ~ 31°C.
1. Coil frost prevention
Coil frost prevention is as same as COOL mode. (a.1.)
The indoor fan maintains the actual speed of the moment.
2. Low outside temperature operation
Low outside temperature operation is as same as COOL mode. (a.2.)
NOTE : Even when the damper is closed while cooling or drying operation is performed, the lower fan may rotate
intermittently.
1. Cold air prevention control
When the compressor is not operating or is starting, and the temperature of indoor heat exchanger and/or the room
temperature is low or when defrosting is being done, the indoor fan will stop or rotate in Very Low speed.
2. High pressure protection
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the
condensing pressure from increasing excessively.
When the temperature of indoor heat exchanger becomes too high, the high pressure protection works.
The indoor fan operates following the cold air prevention control. This mode continues until the temperature of indoor heat
exchanger falls.
3. Defrosting
Defrosting starts when the temperature of outdoor heat exchanger becomes too low.
The compressor stops once, the indoor/outdoor fans stop, the 4-way valve reverses, and the compressor re-starts.
This mode continues until the temperature of outdoor heat exchanger rises or the fixed time passes.

Table of Contents

Other manuals for Mitsubishi Electric MFZ-KA35VA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MFZ-KA35VA and is the answer not in the manual?

Mitsubishi Electric MFZ-KA35VA Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Power Supply220-240 V, 50 Hz
Energy Efficiency Class (Cooling)A++
Energy Efficiency Class (Heating)A+
Seasonal Energy Efficiency Ratio (SEER)6.10
Outdoor Unit Noise Level49 dB
Operating Temperature (Cooling)-10 to +46 °C
Operating Temperature (Heating)-15 to +24 °C