219
APPX
A
Appendix 3 Details of Remote Buffer Memory
(18)Digital clipping enable/disable setting
Set whether to enable or disable the digital clipping function for each channel.
For details on the digital clipping function, refer to the following:
Digital Clipping Function ( Page 117, Section 8.13)
(a) Enabling the setting
Turn on and off Initial data setting request flag (RY9) to enable the setting.
(b) Default value
The default value is Disabled (1) for all channels.
(c) Remote buffer memory address
The remote buffer memory addresses of this area are as follows:
(19)Scaling enable/disable setting
Set whether to enable or disable scaling for each channel.
(a) Enabling the setting
Turn on and off Initial data setting request flag (RY9) to enable the setting.
(b) Default value
The default value is Disabled (1) for all channels.
(c) Remote buffer memory address
The remote buffer memory addresses of this area are as follows:
Remote buffer memory name
Main A/D converter module Extension A/D converter module
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
Digital clipping enable/disable setting 011FH 021FH
Remote buffer memory name
Main A/D converter module Extension A/D converter module
CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
Scaling enable/disable setting 0120H 0220H
00000000000 CH1CH2CH3CH40
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b0b1b2b3b4
0: Enabled
1: Disabled
The values of b4 to b15 are fixed to 0.
00000000000 CH1CH2CH3CH40
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b0b1b2b3b4
0: Enabled
1: Disabled
The values of b4 to b15 are fixed to 0.