EasyManua.ls Logo

Mitsubishi Electric PUD-SWM80YAA User Manual

Mitsubishi Electric PUD-SWM80YAA
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE MANUAL
No. OCH756
R32
January 2021
PARTS CATALOG (OCB756)
CONTENTS
1. REFERENCE MANUAL ································ 2
2. SAFETY PRECAUTION ······························· 3
3. SPECIFICATIONS ······································ 11
4. DATA ··························································· 13
5. OUTLINES AND DIMENSIONS·················· 15
6. WIRING DIAGRAM ····································· 16
7. WIRING SPECIFICATIONS ························ 19
8. REFRIGERANT SYSTEM DIAGRAM ········ 20
9. TROUBLESHOOTING ································ 22
10. MONITORING THE OPERATION DATA
BY THE REMOTE CONTROLLER ············· 65
11. DISASSEMBLY PROCEDURE ··················· 70
Note:
• This manual describes
service data of the outdoor
units only.
AIR TO WATER HEAT PUMP UNITS
OUTDOOR UNIT
[Model Name]
PUD-SWM60VAA
PUD-SWM80VAA
PUD-SWM100VAA
PUD-SWM120VAA
PUD-SWM80YAA
PUD-SWM100YAA
PUD-SWM120YAA
PUD-SHWM60VAA
PUD-SHWM80VAA
PUD-SHWM100VAA
PUD-SHWM120VAA
PUD-SHWM140VAA
PUD-SHWM80YAA
PUD-SHWM100YAA
PUD-SHWM120YAA
PUD-SHWM140YAA
[Service Ref.]
PUD-SWM60VAAR1
PUD-SWM80VAAR1
PUD-SWM100VAAR1
PUD-SWM120VAAR1
PUD-SWM80YAAR1
PUD-SWM100YAAR1
PUD-SWM120YAAR1
PUD-SHWM60VAAR1
PUD-SHWM80VAAR1
PUD-SHWM100VAAR1
PUD-SHWM120VAAR1
PUD-SHWM140VAAR1
PUD-SHWM80YAAR1
PUD-SHWM100YAAR1
PUD-SHWM120YAAR1
PUD-SHWM140YAAR1

Other manuals for Mitsubishi Electric PUD-SWM80YAA

Questions and Answers:

Mitsubishi Electric PUD-SWM80YAA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUD-SWM80YAA
CategoryHeat Pump
LanguageEnglish

Summary

SAFETY PRECAUTION

ALWAYS OBSERVE FOR SAFETY

General safety guidelines before and during repair.

CAUTIONS RELATED TO NEW REFRIGERANT

Specific safety advice for R32 refrigerant.

Warning for service

General Service Warnings

Important warnings and precautions for service personnel.

Cautions for service

Cautions for unit using R32 refrigerant

R32 Refrigerant Safety Checks

Safety checks and procedures for units using R32 refrigerant.

SPECIFICATIONS

OUTLINES AND DIMENSIONS

WIRING DIAGRAM

Outdoor Unit Wiring Diagram

Electrical schematic for the outdoor unit.

WIRING SPECIFICATIONS

REFRIGERANT SYSTEM DIAGRAM

Refrigerant Circuit Diagram

Schematic showing refrigerant flow in heating and defrosting.

REFRIGERANT COLLECTING (PUMP DOWN)

Pump Down Procedure

Procedure for collecting refrigerant before servicing.

TROUBLESHOOTING

Troubleshooting Summary

Overview of self-diagnosis codes and actions.

SELF-DIAGNOSIS ACTION TABLE

Table detailing abnormalities and corrective actions.

TROUBLESHOOTING OF PROBLEMS

Common Problems and Solutions

Common problems and their troubleshooting steps.

FUNCTION OF SWITCHES, CONNECTORS AND JUMPERS

SPECIAL FUNCTIONS

Refrigerant collecting (pump down)

Procedure for collecting refrigerant before unit relocation or disposal.

Outdoor unit operation monitor function

Abnormal Condition Display

Interpretation of LED blinking patterns indicating errors.

MONITORING THE OPERATION DATA BY THE REMOTE CONTROLLER

DISASSEMBLY PROCEDURE

Removing the Compressor (MC)

Procedure for safely removing the compressor unit.