TECHNICAL DATA BOOK
CONTENTS
1. REFERENCE SERVICE MANUAL·············································2
2. SPECIFICATIONS ······································································3
3. OUTLINES AND DIMENSIONS················································30
4. WIRING DIAGRAM···································································54
5. REFRIGERANT SYSTEM DIAGRAM ······································75
6. PERFORMANCE CURVES ······················································80
7. CORRECTION FACTORS ························································82
8. APPLICABLE EXTENSION PIPE FOR EACH MODEL ··········83
9. AIR FLOW DATA ······································································92
10. NOISE CRITERION CURVES·················································111
11. OPTIONAL PARTS···································································124
<Indoor unit>
[Model names]
R410A
PLA-RP·BA(2)
PLA-RP·AA(2)
PEAD-RP·EA(2)
PEAD-RP·GA
PEA-RP·GA
PKA-RP·GAL
PKA-RP·FAL(2)
PCA-RP·GA(2)
PCA-RP·HA
PSA-RP·GA
<Outdoor unit>
[Model names]
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
PUHZ-RP35/50/60/71/100/125/140VHA2
PUHZ-RP35/50/60/71/100VHA3
PUHZ-RP100/125/140YHA2
PUHZ-RP100YHA3
PUHZ-RP200/250YHA2
April 2008
INVERTER
kW Model
No. OCS05
REVISED EDITION-E
Revision:
PLA-RP·BA2 and PUHZ-
RP·HA3 are added in
REVISED EDITION-E.
Some descriptions have been
modified.
Please void OCS05 REVISED
EDITION-D.
OCS05E-1.qxp 08.3.31 9:52 AM Page 1

Other manuals for Mitsubishi Electric PUHZ-RP100VHA3

Questions and Answers:

Mitsubishi Electric PUHZ-RP100VHA3 Specifications

General IconGeneral
SeriesPUHZ-RP
Cooling Capacity10.0 kW
Heating Capacity11.2 kW
RefrigerantR410A
Coefficient of Performance (Heating)3.61
Noise Level (Outdoor Unit)52 dB(A)
Operating Temperature Range (Heating)-15°C to 21°C

Summary

1 REFERENCE SERVICE MANUAL

2 SPECIFICATIONS

2-1. CEILING CASSETTE TYPE

Details specifications for ceiling cassette indoor and outdoor units, including capacity, power, dimensions, and sound levels.

2-2. CEILING-CONCEALED TYPE

Provides specifications for ceiling-concealed indoor and outdoor units, covering various technical parameters.

2-3. WALL MOUNTED TYPE

Details specifications for wall-mounted indoor and outdoor units, including performance and dimensions.

2-4. CEILING SUSPENDED TYPE

Presents specifications for ceiling-suspended indoor and outdoor units, covering technical data and dimensions.

2-5. FLOOR STANDING TYPE

Provides technical specifications for floor-standing indoor and outdoor units, including performance data.

3 OUTLINES AND DIMENSIONS

Detail connecting of branch duct(Both aspects)

Illustrates the detailed connection points for branch ducts on the indoor unit's exterior.

Detail drawing of fresh air intake hole

Shows the dimensions and layout for the fresh air intake hole and optional components.

4 WIRING DIAGRAM

4-1. INDOOR UNIT

Illustrates the internal wiring connections for various indoor unit models and components.

4-2. OUTDOOR UNIT

Details the wiring diagram for outdoor units, including M-NET adapter, power supply, and control connections.

5 REFRIGERANT SYSTEM DIAGRAM

5-1. INDOOR UNIT

Illustrates the refrigerant flow and component layout within the indoor units.

5-2. OUTDOOR UNIT

Shows the refrigerant circuit diagram for outdoor units, detailing components like compressors and heat exchangers.

6 PERFORMANCE CURVES

Cooling capacity

Graphs illustrating cooling capacity ratio vs. outdoor intake air temperature for various indoor wet-bulb temperatures.

Cooling input

Charts showing cooling input ratio versus outdoor intake air temperature under different indoor conditions.

Heating capacity

Curves displaying heating capacity ratio relative to outdoor wet-bulb temperature at various indoor dry-bulb temperatures.

Heating input

Graphs showing heating input ratio as a function of outdoor wet-bulb temperature and indoor dry-bulb temperature.

7 CORRECTION FACTORS

Cooling capacity correction factors

Tables providing correction factors for cooling capacity based on refrigerant piping length and outdoor unit models.

Heating capacity correction factors

Factors to correct heating capacity based on refrigerant pipe length and outdoor unit type.

8 APPLICABLE EXTENSION PIPE FOR EACH MODEL

8-1-1. PIPE LENGTH

Details maximum pipe lengths for 1:1, twin, and triple systems, including OD, thickness, and system type.

8-1-2. ADJUSTING THE AMOUNT OF REFRIGERANT

Instructions on calculating and adjusting refrigerant charge based on pipe length and diameter.

8-1-3. CAPACITY CORRECTION CURVES

Graphs showing capacity reduction due to extended pipe lengths and gas pipe diameter differences.

8-2. PUHZ-RP200·250YHA2

Covers pipe length limits and refrigerant adjustments for twin, triple, and quadruple systems.

8-2-2. TWIN, TRIPLE AND QUADRUPLE SYSTEM

Specifies maximum pipe lengths and refrigerant adjustments for twin, triple, and quadruple systems.

9 AIR FLOW DATA

9-1. OUTLET AIR SPEED AND COVERAGE RANGE

Presents data on outlet air speed and coverage range for various indoor unit models and airflow configurations.

9-2. PLA-RP·BA(2)

Details procedures for fresh air intake and branch duct installation, including hole locations and dimensions.

3. Fresh air intake volume & static pressure characteristics

Shows performance curves for fresh air intake volume and static pressure for different intake configurations.

4. Change of outlet numbers

Explains how to change the number of air outlets and close specific vanes for different airflow patterns.

5. Branch duct and change of outlet numbers

Covers connecting branch ducts and changing outlet configurations for various airflow directions.

9-3. PLA-RP·AA, PLA-RP·AA2

Details how to adjust the width of air outlets and perform fresh air intake installation.

3. Fresh air intake volume & static pressure characteristics

Presents performance curves for fresh air intake volume and static pressure for indoor units.

9-3-2. BRANCH DUCT (Installation at site)

Explains how to install branch ducts, including hole preparation and connection types.

Branch duct airflow rate/static pressure characteristics

Shows static pressure vs. airflow rate curves for various branch duct configurations and airflow directions.

9-4. PEAD-RP·EA,EA2,GA

Provides fan performance curves and corrected airflow factors for PEAD indoor units.

9-5. PEA-RP·GA

Displays fan performance curves (static pressure vs. airflow) for PEA indoor units at 50Hz.

10 NOISE CRITERION CURVES

10-1. INDOOR UNIT

Presents noise criterion curves for various indoor units at different operating modes and speeds.

Sound Data

Provides octave band sound pressure level data (dB(A)) for PEA indoor units at different frequencies.

Position measurement

Illustrates the measurement points and setup for determining indoor unit sound levels.

10-2. OUTDOOR UNIT

Shows noise criterion curves for outdoor units at cooling and heating modes across different frequency bands.

11 OPTIONAL PARTS

11-1. INDOOR UNIT

Lists optional parts for indoor units, including remote controllers, filters, and adapters.

11-2. OUTDOOR UNIT

Details optional parts available for outdoor units, such as M-NET adapters, drain sockets, and filter dryers.