Model | PUY-A36NHA4 |
---|---|
Category | Air Conditioner |
Manufacturer | Mitsubishi Electric |
Refrigerant | R410A |
Outdoor Unit Noise Level | 54 dB(A) |
Operating Temperature Range (Cooling) | -10°C to 46°C |
Sound Pressure Level (Outdoor) | 54 dB(A) |
Type | Heat Pump |
Seasonal Energy Efficiency Ratio (SEER) | 6.10 |
Indoor Unit Noise Level | Not Applicable |
Cooling Capacity (BTU/h) | 36, 000 BTU/h |
Dimensions (H x W x D) | 320 mm (Outdoor Unit) |
Lists indoor unit models and their corresponding service manuals for reference.
Lists outdoor unit models and their corresponding service manuals for reference.
Detailed specifications for inverter ceiling cassette type air conditioners, including capacities and electrical data.
Detailed specifications for inverter wall-mounted type air conditioners, covering dimensions and performance.
Detailed specifications for inverter ceiling-suspended type air conditioners, including performance data.
Detailed specifications for inverter ceiling-concealed type (PEA/PEAD) air conditioners.
Technical specifications for hyper heating inverter models, covering capacities and operational data.
Dimensional drawings and installation details for indoor units, showing key measurements and component locations.
Dimensional drawings and installation details for outdoor units, including piping and mounting points.
Locates the center of gravity (X, Y, Z) for various indoor unit models for installation purposes.
Locates the center of gravity (X, Y, Z) for various outdoor unit models for installation purposes.
Explains the various symbols used in the wiring diagrams for clarity.
Illustrates the refrigerant flow and component layout within indoor units.
Illustrates the refrigerant flow and component layout within outdoor units.
Cooling and heating performance data tables for inverter models under various conditions.
Cooling performance data tables for hyper heating inverter models under various conditions.
Cooling and heating capacity correction factors for inverter models based on refrigerant piping length.
Guidelines for adding refrigerant for inverter models based on pipe length and height difference.
Cooling and heating capacity correction factors for hyper heating inverter models based on piping length.
Guidelines for adding refrigerant for hyper heating inverter models based on pipe length.
Outlet air speed and coverage range data for various indoor unit models.
Details on fresh air intake and branch duct hole locations for indoor units.
Air intake amount and static pressure curves for PCA-A·KA4/5 models.
Indoor fan performance and corrected airflow curves for PEA-A·AA4 models.
Noise criterion curves for various indoor unit models at different fan speeds and external static pressures.
Noise criterion curves for various outdoor unit models at different modes (cooling/heating).
Lists optional parts available for indoor units, categorized by model series.
Lists optional parts available for outdoor units, categorized by model series.
Overview of system control configurations including remote controllers, group control, and M-NET.
Describes additional control options like 2-remote control and remote display for indoor units.