(3) Accessing the C Controller module from the development environment
(personal computer)
(a) Confirmation of power-on
Check that the C Controller module has been started up (powered on).
(b) The C Controller module is ready to connect to C Controller setting utility at the
following timing.
When executing the script file, "STARTUP.CMD":
Upon completion of the RUN LED flashing
When not executing the script file, "STARTUP.CMD":
Fifteen (15) seconds after completion of start or reset
Do not attempt a connection before the above timing after power is turned on.
Changing "Priority" to a larger value in the Option tab of C Controller setting utility
increases the time after which the C Controller module can be connected.
(c) Setting in C Controller setting utility
Start C Controller setting utility on the development environment (personal
computer), and select "192.168.3.3(Default)" for Target module.
Click the button to execute a communication test.
When the following message appears, the C Controller module is accessible.
Figure 6.34 Connection settings
Figure 6.35 Test result
Test