(12)Simple remote debugging of the C Controller module with the supported
Telnet function
By executing a Shell command from the Telnet tool of the development environment
(personal computer), remote debugging of the C Controller module (task information
display, memory dumping, etc.) can be performed with ease.
Simple remote debugging without using Workbench or Tornado is available.
(13)Login user access restriction can prevent illegal access.
Login users can be set (added/deleted) for the C Controller module.
This can restrict parameter writing with FTP or from each utility as well as the usage of
the Telnet function.
Figure 1.15 Telnet function
Figure 1.16 Login user access restriction
Development environment
(personal computer)
Remote control
by Telnet!
Telnet
C Controller module