EasyManua.ls Logo

Mitsubishi Electric Q12DCCPU-V - When Operation Is Not Normal Due to Script File Execution

Mitsubishi Electric Q12DCCPU-V
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
TROUBLESHOOTING
16.2 Troubleshooting
16.2.13 When operation is not normal due to script file execution
16 - 22
9
DEVICE DESCRIPTION
10
MULTIPLE CPU SYSTEM
OVERVIEW
11
MULTIPLE CPU SYSTEM
CONFIGURATION
12
CONCEPT OF MULTIPLE
CPU SYSTEM
13
COMMUNICATIONS
BETWEEN CPU
MODULES
14
PARAMETERS ADDED
FOR MULTIPLE CPU
SYSTEMS
15
STARTING A MULTIPLE
CPU SYSTEM
16
TROUBLESHOOTING
16.2.13 When operation is not normal due to script file execution
The following flowcharts show how to disable script file execution when the C Controller
module does not operate normally due to execution of the user program registered to the
script file.
(1) For the Q12DCCPU-V and Q06CCPU-V
* 1 For restrictions on the functions, refer to the following.
C Controller Module User's Manual (Utility Operation, Programming)
Figure 16.12 Disabling script file execution (for the Q12DCCPU-V and Q06CCPU-V)
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B
Yes
No
No
Yes
Yes
No
Error occurred
Was the user program
started from a script file in the
CompactFlash card?
When the user program was started
from a script file in the standard RAM or
standard ROM, perform the following.
Save a script file, from which the user
program does not start, to the
CompactFlash card, and restart the C
Controller module with the CompactFlash
card set.
Has the script file
execution stopped?
Correct either of the following.
Correct the script file in the
CompactFlash card, or correct the user
program started from the script file in
the CompactFlash card.
End
Has the script file
execution stopped?
Remove the CompactFlash card, and
restart the C Controller module.
Yes
End
No
Compile the user program and
regenerate an execution file according
to the C Controller module
specifications.
Does the endian
format of the execution file
match the specification of the
C Controller module?
*1
1
Script file in the standard RAM or
standard ROM
User program started from a script file
in the standard RAM or standard ROM

Table of Contents

Related product manuals