APPENDICES
Appendix 11 Functions Added by Version Upgrade
APPX - 45
A
I
Appendix 11 Functions Added by Version Upgrade
The tables below shows the functions added and the serial numbers of the C Controller
module and software versions of SW3PVC-CCPU that support the functions.
(1) C Controller module
: Not related to the serial No. or the software version, : N/A
(To the next page)
Table APPX.26 Functions added to the C Controller module
1)Q12DCCPU-V 2)Q06CCPU-V 3)Q06CCPU-V-B
Function
First 5 digits of serial number Software version of
1) 2) 3) SW3PVC-CCPU
Partial change on C Controller modules
Supporting the Q12DCCPU-V
Not supporting the Q06CCPU-V-H01
Version3.03D or later
Supporting more than one QI60 (interrupt module)
12042 or
later
Addition of the function that allows access to a buffer memory in an intelligent
function module through an interrupt routine (interrupt program)
12042 or
later
Change of the battery backup RAM capacity to 512K bytes.
12042 or
later
Addition of the following methods for connecting a GOT.
Bus connection
MELSECNET/H connection (PLC to PLC network)
MELSECNET/10 connection (PLC to PLC network)
CC-Link IE controller network connection
CC-Link connection (intelligent device station)
CC-Link connection (via G4)
Ethernet connection by the 10BASE-T/100BASE-TX interface of the C
Controller module
12042 or
later
(The Ethernet
connection is
Version3.05F or
later)
Addition of the following methods for connecting GX Developer.
Ethernet connection by the 10BASE-T/100BASE-TX interface of the C
Controller module
12042 or
later
Version3.05F or later
Supporting connection with MX Component
12042 or
later
Version3.05F or later
Supporting connection with MELSOFT (GX Developer, GX Works2, and MT
Works2) through Ethernet
12042 or
later
Version3.05F or later
Addition of compact flash card as storing destination drive for parameters
12042 or
later
Version3.05F or later
Addition of the following devices that can be used like programmable controller
CPU
Internal relay (M), data register (D)
Special relay (SM), special register (SD)
12042 or
later
Version3.05F or later
Addition of the function that allows execution of an interrupt routine (interrupt
program) in the event of an interrupt from:
Intelligent function module
Interrupt module
Programmable controller CPU (another CPU)
C Controller module (another CPU)
12042 or
later
Version3.05F or later
Supporting CC-Link IE controller network
Supporting the QJ71GP21-SX and QJ71GP21S-SX
CC IE Control utility has been added.
10012 or
later
Version3.02C or later
Q12DCCPU-V
Q06CCPU-V
Q06CCPU-V-B

Table of Contents

Related product manuals