SYSTEM CONFIGURATION
2.4 Applicable Devices
2 - 33
1
OVERVIEW
2
SYSTEM
CONFIGURATION
3
SPECIFICATIONS
4
FUNCTIONS
5
ACCESS VIA NETWORK
MODULES
6
PREPARATORY
PROCEDURES AND
SETTING
7
I/O NUMBER
ASSIGNMENT
8
MEMORIES AND FILES
(8) Connection from GX Configurator-QP (Q12DCCPU-V only)
Connection from GX Configurator-QP via the following interfaces of the C Controller
module is not allowed.
RS-232 interface
10BASE-T/100BASE-TX interface
Connect the cable to the USB interface.
For connection details, refer to the following.
GX Configurator-QP Operating Manual
(9) Connection from MT Works2 (Q12DCCPU-V only)
Connection from MT Works2 via the RS-232 interface of the C Controller module is
not allowed.
Connect the cable to the 10BASE-T/100BASE-TX interface
*1 *2
or to the USB
interface.
For details on the connection from MT Works2, refer to the user's manual of the
Motion CPU module.
* 1 Connection via the 10BASE-T/100BASE-TX interface is not available with the following C
Controller modules.
• Q12DCCPU-V with a serial number whose first five digits are "12041" or earlier
* 2 For connection via the 10BASE-T/100BASE-TX interface, it is necessary to configure the built-in
Ethernet port open setting in the <<System Settings>> tab of C Controller setting utility.
For details, refer to the following manual.
C Controller Module User's Manual (Utility Operation, Programming)
(10)Connection from MT Developer (Q12DCCPU-V only)
Connection from MT Developer via the following interfaces of the C Controller module
is not allowed.
RS-232 interface
10BASE-T/100BASE-TX interface
Connect the cable to the USB interface.
For details on the connection from MT Developer, refer to the user's manual of the
Motion CPU module.
(11)Connection from MX Component (Q12DCCPU-V only)
Connection from MX Component via the RS-232 interface of the C Controller module
is not allowed.
Connect the cable to the 10BASE-T/100BASE-TX interface
*1 *2
or to the USB
interface.
* 1 Connection via the 10BASE-T/100BASE-TX interface is not available with the following C
Controller modules.
• Q12DCCPU-V with a serial number whose first five digits are "12041" or earlier
* 2 For connection via the 10BASE-T/100BASE-TX interface, it is necessary to configure the built-in
Ethernet port open setting in the <<System Settings>> tab of C Controller setting utility.
For details, refer to the following manual.
C Controller Module User's Manual (Utility Operation, Programming)
For details on the connection from MX Component, refer to the following.
Page App-37, Appendix 10