2 - 69
2 SYSTEM CONFIGURATION
(6) Connection examples of manual pulse generator
Connection of manual pulse generator Connection of manual pulse generator
(Voltage-output/Open collector type) (Differential-output type)
SG
SG
Q173PX
SG
P5
Signal name
A
A
B
0V
5V
SG
P5
A
B
0V
5V
B
Manual pulse
generator side
FG
FG
SG
shield
(Note-2)
: 1 to 3
HA
HB
Q173PX
Manual pulse
generator side
Signal name
: 1 to 3
HA P
HA N
HB P
HB N
HPSEL
(Note-2)
(Note-1)
(Note-1)
:Twisted pair cable
:Twisted pair cable
(Note-1) : The 5V(P5)DC power supply from the Q173PX must not be connected if a separated
power supply is used as the Manual pulse generator/Incremental synchronous
encoder power supply.
Use a 5V stabilized power supply as a separated power supply. Any other power supply
may cause a failure.
(Note-2) : Connect HPSEL
to the SG terminal if the manual pulse generator (differential output
type/incremental synchronous encoder is used.
CAUTION
If a separate power supply is used as the manual pulse generator/incremental synchronous
encoder power supply, use a 5V stabilized power supply. Any other power supply may cause a
failure.