EasyManua.ls Logo

Mitsubishi Electric Q173CPU - Division

Mitsubishi Electric Q173CPU
472 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 16
7 OPERATION CONTROL PROGRAMS
F/FS G
7.4.5 Division : /
Format (S1)/(S2) Number of basic steps 4
[Usable data]
Usable Data
Word device Constant
Setting
data
Bit device
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
(S1) —
— —
(S2) —
— —
: Usable
[Setting data]
Setting data Description Data type of result
(S1) Dividend data
(S2) Divisor data
Data type of (S1) or (S2)
which is greater
[Functions]
(1) The data specified with (S1) is divided by the data specified with (S2) to find a
quotient.
(2) When (S1) and (S2) differ in data type, the data of the smaller data type is
converted into that of the greater type before operation is performed.
[Errors]
(1) An operation error will occur if:
• (S2) is 0; or
• (S1) or (S2) is an indirectly specified device and its device No. is outside the
range.
[Program examples]
(1) Program which divides K456 by #0 and substitutes a quotient to W0
W0 = K456 / #0
#0
123
W0
3
456
/
(2) Program which divides #0F by #10 and substitutes a quotient to D0L
D0L = #0F / #10
100.3722683
/
123
D1
100
D0
#3 #2
12345.789
#1 #0
#10
The 64-bit floating-point type data are used for division, and the quotient is
converted into the 32-bit integer type and then substituted.