5 - 27
5 OPERATION CONTROL PROGRAMS
F/FS G
5.6 Standard Functions
5.6.1 Sine : SIN
Format SIN(S) Number of basic steps 2
[Usable data]
Setting
data
Usable Data
Bit device
Word device Constant
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
(S)
: Usable
[Setting data]
Setting data Description Data type of result
(S)
Angle data on which SIN (sine) operation will be
performed
Floating-point type
[Functions]
(1) SIN (sine) operation is performed on the data specified with (S).
(2) The data specified with (S) is in an angle (degree) unit.
(3) If (S) is an integer type, it is converted into a floating-point type before operation is
performed.
[Errors]
(1) An operation error will occur if:
• (S) is an indirectly specified device and its device No. is outside the range.
[Program examples]
(1) Program which performs the SIN operation of D0 and substitutes the result to #0F
#0F = SIN(D0)
D0 45
#3 #2
0.70710678118655
#1 #0
#0F