EasyManua.ls Logo

Mitsubishi Electric Q173DSCPU - OFF (Normally Closed Contact)

Mitsubishi Electric Q173DSCPU
556 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 - 54
5 OPERATION CONTROL PROGRAMS
F/FS G
5.8.2 OFF (Normally closed contact) : !
Format !(S) Number of basic steps 2
[Usable data]
Setting
data
Usable Data
Bit device
Word device Constant
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
(S)
: Usable
[Setting data]
Setting data Description Data type of result
(S) Bit device used in bit conditional expression Logical type (true/false)
[Functions]
(1) True is returned when the bit device specified with (S) in a bit conditional
expression is OFF (0), or false is returned when that bit device is ON (1).
[Errors]
(1) An operation error will occur if:
• (S) is an indirectly specified device and its device No. is outside the range.
[Program examples]
(1) Program which resets M100 when M0 is OFF (0)
RST M100 = !M0