5 - 86
5 OPERATION CONTROL PROGRAMS
F/FS G
5.12.4 Torque limit value individual change request : CHGT2
QDS
Format CHGT2((S1), (S2), (S3)) Number of basic steps 5
[Usable data]
Setting
data
Usable Data
Bit device
Word device Constant
Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
Coasting
timer
16-bit
integer
type (K/H)
32-bit
integer type
(K/H, L)
64-bit
floating
point
type (K)
(S1) — — — — —
— — — — —
(S2) —
— —
—
— —
(S3) —
— —
—
— —
: Usable
[Setting data]
Setting data Description Data type of result
(S1)
Axis No. to which torque limit value change request
will be given
—
(S2) Positive direction torque limit value (0.1[%])
(S3) Negative direction torque limit value (0.1[%])
[Functions]
(1) The torque limit value of the axis specified with (S1) is changed to the positive
direction torque limit value specified with (S2) and negative direction torque limit
value specified with (S3).
The positive direction torque limit value restricts the forward rotation (CCW)
driving torque and reverse rotation (CW) regenerative torque of the servo motor,
and negative direction torque limit value restricts the reverse rotation (CW) driving
torque and forward rotation (CCW) regenerative torque of the servo motor.
(2) Any axis that has completed a servo startup can be changed in torque limit value
any time, independently of the status, starting, stopping, servo ON or servo OFF.
(3) When the CHGT2 instruction is executed to the mechanical system output module
in the virtual mode, set 300[%] as the torque limit value of output module. When
the torque limit value of output module is indirectly specified with a device, a minor
error (error code: 6260) will occur, and the individual change of torque limit value
is not executed.
(4) The axis No. that may be set at (S1) is within the following range.
Q173DSCPU Q172DSCPU
1 to 32 1 to 16
(5) (S2) and (S3) cannot be omitted. When only either torque limit value is changed,
set "-1" as the setting data not to change.