CHAPTER 6 CPU MODULE
6
6.2 Specifications
6.2.5 Universal model QCPU
Item
Universal model QCPU
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
Max. number
of files stored
Program memory
32
*7
64
*7
Memory card (RAM) ----
319 (When the
Q3MEM-8MBS is
used)
Memory card
(ROM)
Flash card ---- 288
ATA card ---- 511
Standard RAM ----
4 files (each one of the following files: file register file, local device
file, sampling trace file, and module error collection file)
Standard ROM 128
Max. number of intelligent
function module parameters
Initial
setting
512 2048
Refresh 256 1024
No. of times of writing data into the program
memory
Max. 100000 times
*4
No. of times of writing data into the standard
ROM
Max. 100000 times
*5
No. of I/O device points
(No. of points usable on program.)
8192 points (X/Y0 to 1FFF)
No. of I/O points
(No. of points accessible to the actual I/O
module.)
256 points
(X/Y0 to FF)
1024 points
(X/Y0 to 3FF)
2048 points
(X/Y0 to 7FF)
No. of device points
Internal relay [M]
*6
8192 points by default (M0 to 8191) (changeable)
Latch relay [L]
*6
8192 points by default (L0 to 8191) (changeable)
Link relay [B]
*6
8192 points by default (B0 to 1FFF) (changeable)
Timer [T]
*6
2048 points by default (T0 to 2047) (changeable)
(Sharing of low- and high-speed timers)
The low- and high-speed timers are specified by the instructions.
The measurement unit of the low- and high-speed timers is set up by parameters.
(Low-speed timer: 1 to 1000ms, 1ms unit, 100ms by default)
(High-speed timer: 0.01 to 100ms, 0.01ms unit, 10.00ms by default)
Retentive timer [ST]
*6
0 points by default (sharing of the low- and high-speed retentive timers) (changeable)
The low- and high-speed retentive timers are specified by the instructions.
The measurement unit of the low- and high-speed retentive timers is set up by
parameters.
(Low-speed retentive timer: 1 to 1000ms, 1ms unit, 100ms by default)
(High-speed retentive timer: 0.01 to 100ms, 0.01ms unit, 10.00ms by default)
Counter [C]
*6
Normal counter, 1024 points by default (C0 to 1023) (changeable)
Data register [D]
*6
12288 points by default (D0 to 12287) (changeable)
Extended data register [D] ---- 0 points by default (changeable)
Link register [W]
*6
8192 points by default (W0 to 1FFF) (changeable)
Extended link register [W] ---- 0 points by default (changeable)
Annunciator [F]
*6
2048 points by default (F0 to 2047) (changeable)
Edge relay [V]
*6
2048 points by default (V0 to 2047) (changeable)
Link special relay [SB]
*6
2048 points by default (SB0 to 7FF) (changeable)
Link special register [SW]
*6
2048 points by default (SW0 to 7FF) (changeable)