4 - 2 4 - 2
MELSEC-Q
4 SETUP AND PROCEDURE BEFORE STARTING THE OPERATION
4.2 Procedure Before Starting the Operation
The figure below shows the steps that should be followed before starting the
QD62(E/D) operation.
Perform the initial setting using the GX
Configurator-CT (see Section 7.4).
Perform settings using the GX Developer
(see Section 4.5)
Start
Module mounting
Mount the QD62(E/D) in the specified slot.
Wiring
Wire external devices to the QD62(E/D).
Intelligent function module switch setting
Use the GX Configurator-CT?
Yes
No
Initial setting
Using the FROM/TO commands, create
a sequence program for writing initial values.
Initial setting
Perform automatic
refresh setting?
No
Yes
Automatic refresh setting
Perform the automatic refresh setting
using the GX Configurator-CT
(see Section 7.5).
Programming
Create and check a counter processing
program without using the FROM/TO commands.
Programming
Create and check a counter processing
program using the FROM/TO commands.
Operation
4