CHAPTER 7 PARAMETER SETTING
7
7.6 Interrupt Settings
(3) Setting example
(a) Starting the interrupt program of the master station (station number 0) when RX100
turns on
The following is a setting example to execute the interrupt program corresponding to the interrupt pointer I50
when RX100 turns on by turning on the corresponding switch on the slave station side.
1. Set the interrupt setting parameters for the master/local module (station number 0) in the
"Interrupt Settings" window as shown below.
2. Set the parameters in the "Intelligent Function Module Interrupt Pointer Setting" window as shown
below.
By using link special relay (SB) and link special register (SW) as an interrupt condition device, an interrupt program can be
started in case of data link error. ( Page 473, Appendix 3, Page 493, Appendix 4)
1
2
RX100
I50
SM400
IRET
Interrupt program
execution
Receive
processing
Master station
(Station No.0)
Slave station
(Station No.1)
ONON
Master/local module
Switch
CPU module
1
2
Set the same SI number as the interrupt settings.