(5) Checking the network status
After starting up the system, check whether data link can be normally performed using the CC-Link IE Field
Network diagnostics in GX Works2.
1. Connect GX Works2 to the master station.
2. In the menu, start up the CC-Link IE Field Network diagnostics.
[Diagnostics] [CC IE Field Diagnostics]
If the following display appears, data link is normal.
If a mark, such as , , and , is displayed in "Network Status", an error has occurred. Use
the CC-Link IE Field Network diagnostics to identify the cause of the error and take actions.
( Page 208, Section 9.2)
If an error has occurred in the local station (station number 1), the window appears as follows.