10.8 JP/GP.SEND (Sending Data to the Programmable Controller on Another Station)
10.8 JP/GP.SEND (Sending Data to the Programmable
Controller on Another Station)
This instruction sends data to the programmable controller on another station.
*1 Local devices and file registers set for each program cannot be used.
(1) Setting data
Setting
data*
1
Available device
Internal device
(System, user)
File
register
R, ZR
Link direct device
J\
Intelligent function
module device
U\G
Index register
Zn
Constant
Others
Bit Word Bit Word K, H $
(S1)
(S2)
(D1)
Setting data Description Set by Data type
Jn
Own station's network No. (1 to 239, 254)
254: Network specified in Valid Module During Other Station Access
User
16-bit binary
Un
Start I/O number of the master/local module of the own station
(00 to FE
H
: Upper two digits of the I/O number expressed in three
digits)
(S1) Start device of the own station where control data is stored
Device name
(S2) Start device of the own station where send data is stored
(D1)
The device of the own station that turns on for one scan upon
completion of the instruction.
If the instruction fails, (D1)+1 also turns on.
System Bit
JP.SEND
Start contact
GP.SEND
Start contact
JP.SEND Jn
GP.SEND Un
(S1) (S2) (D1)
(S1) (S2) (D1)