310
*1 If Completion status ((S1)+1) is "Channel in use (dedicated instruction) (error codes: D25A
H
and D25B
H
)", data is not
stored.
(b) Request data (a user sets all)
(S1)+10
Response data
length
Stores the response data count (word).
(Word count of data to be stored in own station start device (D1)
where response data is stored)
2: Remote RUN/STOP
System
(S1)+11 Clock set flag
The valid or invalid status of data after (S1)+12 is stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
0: Invalid
1: Valid
System
(S1)+12 to
(S1)+15
Clock data of
abnormal end
Clock data of abnormal end are stored in BCD format.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
When the target station is QnACPU, "00
H
" is stored in the year (the
first two digits of the year).
System
(S1)+16
Error-detected
station's network
No.
*1
The network No. of the station in which an error was detected is
stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
1 to 239: Network No.
System
(S1)+17
Error-detected
station number
*1
The station number of the station in which an error was detected is
stored.
(Data is stored when "1: Data at the time of abnormal end is set in
the area starting from (S1)+11." is set in the abnormal end type in
(S1)+0.) The stored data is not cleared even if the dedicated
instruction is normally completed.
Master station: 125 (7D
H
)
Local station, intelligent device station, submaster station: 1 to 120
System
Device Item Setting data Remote RUN Remote STOP
(S2)+0 Request type
0010
H
: When station No. is specified by (S1)+5
0030
H
: When all stations or groups are specified by (S1)+5
(S2)+1 Sub-request type
0001
H
: Remote RUN
0002
H
: Remote STOP
Device Item Setting data Setting range Set by
(S1)+12
(S1)+13
(S1)+14
(S1)+15
Month (01
H to 12H)
Hour (00
H to 23H)
Second (00
H to 59H)
Day (01
H to 31H)
Minute (00
H to 59H)
00
H (Sun.) to 06H (Sat.)
Day of week (00
H to 06H)
Year (00H to 99H), first 2 digits
Year (00
H to 99H), last 2 digits
b15 b8 b7 b0