(d) UINI instruction setting
The following table lists values set in UINI instruction devices.
(5) Program example
Device Item Set value
(S1)+0 D600 Unused
(S1)+1 D601 Completion status
(The system sets this item.)
(S1)+2 D602 Target station setting
1
H
(S1)+3 D603 Own station number ZR0 value
(S1)+4 to
(S1)+9
D604 to D609 Unused
Abnormal end processing program
Normal completion processing program
Control data
Execute the
UINI instruction.