APPX
Appendix 3 Buffer Memory Areas
177
A
CH1 Alert output setting (Rate alarm)
Set whether to enable or disable the alert output of the rate alarm.
For details on the alert output function, refer to the following.
Page 30 Alert Output Function
If a value other than the above is set, an alert output setting (Rate alarm) range error (error code: 1B8H) occurs.
■Buffer memory address
The following shows the buffer memory address of this area.
•CH Alert output setting (Rate alarm)
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9).
■Default value
The default value is Disable (1) for all channels.
Alert output setting [Q compatible mode]
When the Q compatible mode function is used, set whether to enable or disable the alert output of process alarms and rate
alarms.
■Buffer memory address
The following shows the buffer memory address of this area.
Only the R60AD8-G can use this area.
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9).
■Default value
• b0 to b7: The default value is Process alarm disabled (1).
• b8 to b15: The default value is Rate alarm disabled (1).
Setting value Setting content
0 Enable
1 Disable
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16
513 713 913 1113 1313 1513 1713 1913 2113 2313 2513 2713 2913 3113 3313 3513
(1) 0: Process alarm enabled, 1: Process alarm disabled
(2) 0: Rate alarm enabled, 1: Rate alarm disabled
Buffer memory name CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8
Alert output setting (Process alarm)/Alert output
setting (Rate alarm)
48
CH1CH2CH3CH4CH5CH6CH7CH8CH1CH2CH3CH4CH5CH6CH7CH8
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b0b1b2b3b4
(1)(2)