4 OPERATION CONTROL PROGRAMS
4.6 Bit Operations
139
4
Bit logical AND: &
Setting data
Usable data
: Usable
Description, data type of result
Processing details
The bit-by-bit logical product of the data specified with (S1) and the data specified with (S2) is found.
When (S1) and (S2) differ in data type, the data of the smaller data type is converted into that of the greater type before
operation is performed. At this time, note that signed data is converted.
Operation error
An operation error will occur if:
(S1) or (S2) is an indirectly specified device and its device No. is outside the range.
Program example
Program which ANDs #0 and #1 and substitutes the result to D0
Format Number of basic steps Usable steps
F/FS G
(S1)&(S2) 7 
Setting
data
Usable Data
Bit
device
Word device Constant Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
16-bit
integer
type
(K/H)
32-bit
integer
type
(K/H, L)
64-bit
floating
point
type (K)
(S1) 
(S2) 
Setting data Description Data type of result
(S1) Data which will be ANDed bit-by-bit Data type of (S1) or (S2) which is greater
(Integer type)
(S2)
0#0 111111
b15 b0
D0
b15 b0
000000 000
&
0#1 101101
b15 b0
001000 000
0 101101000000 000
D0 = #0 & #1