4 OPERATION CONTROL PROGRAMS
4.9 Type Conversions
171
4
Unsigned 32-bit integer value conversion: ULONG
■Usable Data
: Usable
■Description, data type of result
• The data specified with (S) is converted into an unsigned 32-bit integer value.
• The data range of (S) is 0 to 4294967295.
• When (S) is a 64-bit floating-point type, its fractional portion is rounded down before conversion is made.
• If (S) is a 32-bit integer type, its value is returned unchanged, with no conversion processing performed.
An operation error will occur if:
• The (S) data is outside the range 0 to 4294967295.
• (S) is an indirectly specified device and its device No. is outside the range.
■Program which converts the data of D0 into an unsigned 32-bit integer value and substitutes
the result to #0L
Format Number of basic steps Usable steps
F/FS G
ULONG(S) 4
Setting
data
Usable Data
Bit
device
Word device Constant Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
16-bit
integer
type
(K/H)
32-bit
integer
type
(K/H, L)
64-bit
floating
point
type (K)
(S)
Setting data Description Data type of result
(S) Data which will be converted into unsigned 32-bit integer value 32-bit integer type
#0L = ULONG(D0)
K65535L
#1 #0
#0L
(H0000FFFF)
D0 K-1
(HFFFF)
Unsigned value is K65535