APPENDICES APPENDIX
Appendix 1 Processing Times
333
A
Deploying time for cam data
The time is takes to deploy one cam file from the standard ROM to the open area is shown below. The search time can vary
substantially depending on the cam file that is stored, and the number of other files stored. The values contained in the
following tables should therefore be taken as a set of general guidelines to processing time rather than as being strictly
accurate.
Stroke ratio data format
Coordinate data format
Cam auto-generation
■Cam for rotary cutter
■Easy stroke ratio cam
■Advanced stroke ratio cam
Cam resolution Number of registered cams Processing time [ms]
256 16 8.5
1024 20
32768 2 118
128 125
Cam resolution Number of registered cams Processing time [ms]
256 16 12
1024 20
32768 2 612
128 614
Cam resolution Number of registered cams Processing time [ms]
1024 256 33
1024 94
Cam resolution Number of registered cams Number of sections Processing time [ms]
256 256 1 36
1024 94
Cam resolution Number of registered cams Number of sections Processing time [ms]
256 1024 1 103
180 93
360 105
4096 1 107
180 112
360 115
32768 128 1 103
180 78
360 83