72
2 MOTION DEDICATED PLC INSTRUCTION
2.2 Motion Dedicated PLC Instruction
Machine program operation start request from the PLC CPU to
the Motion CPU: M(P).MCNST/D(P).MCNST
*1 : Instruction (M(P).MCNST: M, D(P).MCNST: D)
Setting data
Usable devices
: Usable, : Usable partly
*1 Local devices cannot be used.
*2 Setting data (n1) to (D1): Index qualification possible (except constant)
Description, range, setting side, data type
*1 Motion CPU cannot be set as CPU No.1 in the Multiple CPU configuration.
Control data
Machine positioning data area
Refer to the following for the machine positioning data area.
MELSEC iQ-R Motion Controller Programming Manual (Machine Control)
Instruction Condition Sequence program
*1
MP.MCNST
DP.MCNST
M.MCNST
D.MCNST
Setting
data
*2
Usable devices
Internal devices
(System, User)
File register Link direct
device J\
Module access
device U\G
Index
register
Z
Constant Others
Bit Word Bit Word Bit Word Bit Word Decimal K,
Hexadecimal
H
Real
character
string
(n1) 
(S1)
*1
*1
(S2) 
(D1)
*1
*1
Setting data Description Setting range Set by Data type
(n1) (First I/O No. of the target CPU)/16
Value to specify actually is the following.
*1
CPU No.2: 3E1H, CPU No.3: 3E2H, CPU No.4: 3E3H
3E1H to 3E3H User 16-bit binary
(S1) First device of the self CPU where the control data is stored. User Word
(S2) First device of the self CPU where the machine positioning data area is stored. User Word
(D1) Complete devices
(D1+0): Device which make turn on for one scan at accept completion of instruction.
(D1+1): Device which make turn on for one scan at accept abnormal completion of
instruction. ("D2+0" also turns on at the abnormal completion.)
System Bit
Device (S1) Item Setting data Setting range Set by
+0 Complete status The status at the instruction completion is stored.
0: No error (Normal completion)
Except 0: Error code
System
+1 Number of machine
positioning data points
Set the size of the machine positioning data area in units of words. 78 to 5444 User
(D1)(S2)(S1)(n1)
P.MCNST
Command
(D1)(S2)(S1)(n1)
.MCNST
Command