1 FUNCTIONS
1.1 Pulse Input Modes and Counting Methods
13
1
1 FUNCTIONS
This chapter describes the functions for the high-speed counter module and the setting methods. For details on I/O signals
and buffer memory areas, refer to the following.
Page 55 Input signals
Page 57 Output signals
Page 62 Details of buffer memory addresses
This chapter describes the I/O numbers (X/Y), buffer memory addresses, and external I/O terminals for CH1.
To check the I/O numbers (X/Y) for CH2, refer to the following.
Page 54 List of I/O signals
To check the buffer memory addresses for CH2, refer to the following.
Page 60 List of buffer memory addresses
1.1 Pulse Input Modes and Counting Methods
This section describes the pulse input modes and the counting methods.
Types of pulse input modes
The following six pulse input modes are prepared: 1-phase pulse input (1 multiple/2 multiples), CW/CCW pulse input, and 2-
phase pulse input (1 multiple/2 multiples/4 multiples).
Pulse input modes and count timing
Pulse input mode Count timing
1-phase multiple of 1 For counting up Counts on the rising edge () of A.
B and CH1 Down count command (Y3) are off.
For counting down Counts on the falling edge () of A.
B or CH1 Down count command (Y3) is on.
1-phase multiple of 2 For counting up Counts on the rising edge () and the falling edge
() of A.
B and CH1 Down count command (Y3) are off.
For counting down Counts on the rising edge () and the falling edge
() of A.
B or CH1 Down count command (Y3) is on.
CW/CCW For counting up Counts on the rising edge () of A.
B is off.
For counting down A is off.
Counts on the rising edge () of B.
φA
φB and
CH1 Down
count command
(Y3)
φA
φB or
CH1 Down
count command
(Y3)
φA
φB and
CH1 Down
count command
(Y3)
φA
φB or
CH1 Down
count command
(Y3)
φA
φB
φA
φB