Appendix 3 Buffer Memory Areas
CH1 Sampling/cycle counter flag
• When the sampling counter function or cycle pulse counter function is selected, the operating status of the selected
function is stored in this area.
• Either of the following values is stored based on the operating status of the function.
■Buffer memory address
The following shows the buffer memory address of this area.
CH1 Latch count value
• The latch count value is stored in this area during the execution of the latch counter function.
• The range of the stored value is between -2147483648 and 2147483647 (32-bit signed binary value).
■Buffer memory address
The following shows the buffer memory address of this area.
Although the storage addresses differ between the latch count value and cycle pulse count current value, the
stored values are always the same (updated simultaneously). Therefore, when the latch counter function or
cycle pulse counter function is executed, the latch count value and cycle pulse count current value do not hold
their previous values.
CH1 Sampling count value
• The sampling count value is stored in this area during the execution of the sampling counter function.
• The range of the stored value is between -2147483648 and 2147483647 (32-bit signed binary value).
■Buffer memory address
The following shows the buffer memory address of this area.
CH1 Cycle pulse count previous value
• The cycle pulse count previous value is stored in this area during the execution of the cycle pulse counter function.
• The range of the stored value is between -2147483648 and 2147483647 (32-bit signed binary value).
■Buffer memory address
The following shows the buffer memory address of this area.
Operating status Stored value
Function stopped 0
Function being executed 1
Buffer memory address name CH1 CH2
CH Sampling/cycle counter flag 11 43
Buffer memory address name CH1 CH2
CH Latch count value 12 to 13 44 to 45
Buffer memory address name CH1 CH2
CH Sampling count value 14 to 15 46 to 47
Buffer memory address name CH1 CH2
CH Cycle pulse count previous value 16 to 17 48 to 49