APPENDICES
Appendix 4 Operation Examples of When the Remote Head Module Is Mounted
69
A
Appendix 4 Operation Examples of When the Remote
Head Module Is Mounted
This section describes operation examples of when the remote head module is mounted.
System configuration example
The following system configuration is used to explain an example of operation.
*1 In the RX/RY setting of the master station, set 1000H to 100FH as the start I/O number of the high-speed counter module.
(1) Master station (Network number 1, station number 0)
Power supply module: R61P
CPU module: R04CPU
Master/local module: RJ71GF11-T2 (Start I/O number: 0000H to 001FH)
Input module: RX41C4 (Start I/O number: 0020H to 003FH)
Output module: RX10R2 (Start I/O number: 0040H to 004FH)
(2) Intelligent device station (Network number 1, station number 1)
Power supply module: R61P
Remote head module: RJ72GF15-T2
High-speed counter module: RD62P2 (Start I/O number: 0000H to 000FH
*1
)
(1) (2)