406
12 DATA USED FOR POSITIONING CONTROL
12.2 List of Buffer Memory Addresses
The following shows the relation between the buffer memory addresses for mark detection function and the various items.
k: Mark detection setting No. - 1
Memory area Item Buffer memory address
Mark detection setting parameters [Pr.800] Mark detection signal setting 54000+20k
[Pr.801] Mark detection signal compensation time 54001+20k
[Pr.802] Mark detection data type 54002+20k
[Pr.803] Mark detection data axis No. 54003+20k
[Pr.804] Mark detection data buffer memory No. 54004+20k
54005+20k
[Pr.805] Latch data range upper limit value 54006+20k
54007+20k
[Pr.806] Latch data range lower limit value 54008+20k
54009+20k
[Pr.807] Mark detection mode setting 54010+20k
Mark detection control data [Cd.800] Number of mark detection clear request 54640+10k
[Cd.801] Mark detection invalid flag 54641+10k
[Cd.802] Latch data range change request 54642+10k
Mark detection monitor data [Md.800] Number of mark detection 54960+80k
[Md.801] Mark detection data storage area (1 to 32) 1 54962+80k
54963+80k
2 54964+80k
54965+80k
3 54966+80k
54967+80k
ļƒ•ļƒ•
32 55024+80k
55025+80k

Table of Contents