8 CONTROL SUB FUNCTIONS
8.8 Functions Related to Stop
Control details
The following drawing shows a step operation during a "deceleration unit step".
RD77MS4 operation example
The following drawing shows a step operation during a "data No. unit step".
RD77MS4 operation example
Precautions during control
When step operation is carried out using interpolation control positioning data, the step function settings are carried out for
the reference axis.
When the step valid flag is ON, the step operation will start from the beginning if the positioning start signal is turned ON
while "[Md.26] Axis operation status" is "step standby". (The step operation will be carried out from the positioning data set
in "[Cd.3] Positioning start No.".)
BUSY signal
Positioning
[Cd. 35] Step valid flag
Positioning data No.
[Da.1] Operation pattern
No.10
11
No.11
01
t
OFF
ON
ON
ON
OFF
V
ON
OFF
OFF
ON
Positioning start signal
[Y10, Y11, Y12, Y13]
[X10, X11, X12, X13]
Positioning complete signal
([Md.31] Status: b15)
No positioning data No. unit, so operation pattern
becomes one step of unit for carrying out automatic
deceleration.
BUSY signal
Positioning
[Cd. 35] Step valid flag
Positioning data No.
[Da.1] Operation pattern
No.10
11
No.11
01
[Cd.36] Step start information
00H 01H 00H
OFF
ON
OFF
OFF
ON
ON
ON
OFF
t
V
Positioning start signal
[Y10, Y11, Y12, Y13]
[X10, X11, X12, X13]
Positioning complete signal
([Md.31] Status: b15)
Operation pattern becomes one step of positioning data No. unit,
regardless of continuous path control (11).