9 COMMON FUNCTIONS
9.4 External Input Signal Select Function
311
9
Precautions on parameter setting
The logic switching parameters are validated when the PLC READY signal [Y0] is turned OFF to ON. (The logic is negative
right after power-on.)
If the logic of each signal is set erroneously, the operation may not be carried out correctly. Before setting, check the
specifications of the equipment to be used.
Input filter setting method for external input signals
The input filter is used to suppress chattering when the external input signal is chattering by noise, etc.
The setting area of the input filter varies by the input type of "[Pr.116] FLS signal selection" to "[Pr.119] STOP signal selection".
External input signals from the external device connected with the Simple Motion module
(upper/lower stroke limit signal (FLS/RLS), near-point dog signal (DOG), stop signal (STOP),
and external command signal/switching signal (DI))
Use the following parameter to set the input filter of the external input signals from the external device connected with the
Simple Motion module (upper/lower stroke limit signal (FLS/RLS), near-point dog signal (DOG), stop signal (STOP), and
external command signal/switching signal (DI)).
Precautions
"[Pr.153] External input signal digital filter setting" is not a parameter for each axis.
"[Pr.153] External input signal digital filter setting" becomes valid when the power supply is turned ON, the CPU module is
reset, or the PLC READY signal [Y0] is turned ON.
When lengthening the filter setting time, the signal detection timing will be slow.
When "[Pr.153] External input signal digital filter setting" is set with a value other than "0 to 6", note that the module may
cause a failure.
Input type of "[Pr.116] FLS signal selection" to "[Pr.119] STOP
signal selection"
Setting area
0: Simple Motion module [Pr.153] External input signal digital filter setting
1: Servo amplifier Input filter setting (PD11)
(Servo parameter)
2: Buffer memory No setting (No input filter when the buffer memory is set.)
Setting item Initial value Setting details
[Pr.153] External input signal
digital filter setting
6666H Filter setting 1 0H: 3.2 ms
1H: 2.4 ms
2H: 1.6 ms
3H: 1.2 ms
4H: 0.8 ms
5H: 0.4 ms
6H: 0.2 ms
Filter setting 2
Filter setting 3
Filter setting 4
Filter setting 5
SIN3 SIN2 SIN1SIN4
b15 b12 b8 b0b4
b15 b12 b8 b0b4
SIN8
SIM7 SIM6 SIM5
b15 b12 b8 b0b4
SIN12 SIN11 SIN10 SIN9
b15 b12 b8 b0b4
SIN16 SIN13SIN15 SIN14
b15 b12 b8 b0b4
SIN20 SIN17SIN19 SIN18