14 TROUBLESHOOTING
14.4 List of Warning Codes
589
14
0C40H Outside operation
cam No. range
"[Cd.601] Operation cam No." is other than 1 to 256.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of 1 to 256.
0C41H Read cam not
registered
Cam data of the specified cam No. does not exist on the
cam open area during the cam data reading operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Specify the cam No. of an existing cam data.
When writing the cam data from a programming tool,
turn the PLC ready signal from OFF to ON and open
the cam data on the cam open area.
0C42H Outside cam data
first position range
"[Cd.602] Cam data first position" is outside the range
of "1 to Cam resolution" for the stroke ratio data
format cam.
"[Cd.602] Cam data first position" is outside the range
of "0 to (Coordinate number - 1)" for the coordinate
data format cam.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of "1 to Cam resolution"
for the stroke ratio data format cam.
Set a value within the range of "0 to (Coordinate
number - 1)" for the coordinate data format cam.
0C43H Outside number of
cam data operation
points range
"[Cd.603] Number of cam data operation points" is
outside the range of 1 to 4096 for the stroke ratio data
format cam.
"[Cd.603] Number of cam data operation points" is
outside the range of 1 to 2048 for the coordinate data
format cam.
First position and number of operation points which
exceed the cam resolution or coordinate number are
set during the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of 1 to 4096 for the
stroke ratio data format cam.
Set a value within the range of 1 to 2048 for the
coordinate data format cam.
Set "Cam data first position + (Number of cam data
operation points - 1)" not to exceed the cam
resolution.
Set "Cam data first position + (Number of cam data
operation points - 1)" not to exceed the number of
coordinates.
0C44H Outside cam data
format range
"[Cd.604] Cam data format" is other than 1 or 2 during
the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set 1 or 2.
0C45H Outside cam
resolution/coordinate
number range
"[Cd.605] Cam resolution/coordinate number" is other
than "256/512/1024/2048/4096/8192/16384/ 32768"
for the stroke ratio data format cam during the cam
data writing operation.
"[Cd.605] Cam resolution/coordinate number" is
outside the range of "2 to 16384" for the coordinate
data format cam during the cam data writing
operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of "256/512/1024/ 2048/
4096/8192/16384/32768" for the stroke ratio data
format cam.
Set a value within the range of 2 to 16384 for the
coordinate data format cam.
0C46H Outside cam data
starting position
range
"[Cd.606] Cam data starting point" is outside the range
from "0 to (Cam resolution - 1)" during the cam data
writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set a value within the range of "0 to (Cam resolution -
1)".
0C47H Cam storage area
capacity over
The free area in the cam storage area is insufficient
during the cam data writing operation.
The writable area is insufficient due to the decoupling
of free area.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Decrease the number of cam data (number of cams,
cam resolution, and coordinate number).
Erase the cam data and rewrite it.
0C48H Cam open area
capacity over
The free area in the cam open area is insufficient
during the cam data writing operation.
The writable area is insufficient due to the decoupling
of free area.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Decrease the number of cam data (number of cams,
cam resolution, and coordinate number).
Erase the cam data and rewrite it.
0C49H Coordinate data
error
Input value of coordinate data is a negative value
during the cam data writing operation.
Input value of coordinate data is not "X
n
< X
n+1
"
during the cam data writing operation.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Set the Input value of coordinate data to 0 or more.
Set the Input value of coordinate data to "X
n
< X
n+1
".
0C4AH Cam data reading
operation inhibit
Cam data reading operation is executed with the cam
data read password set.
[Operation status at warning occurrence]
Cam data writing/reading is not executed.
Delete the cam data read password with a
programming tool.
Warning code
(Hexadecimal)
Warning name Error details and causes Remedy