614
14 TROUBLESHOOTING
14.5 List of Error Codes
*1 Setting condition: "[Cd.16] Inching movement amount (A) [Pr.31] JOG speed limit value"
Use the following values for (A).
Unit setting Operation cycle
0.444 ms 0.888 ms 1.777 ms 3.555 ms
When unit is set to pulse 2250 1125 562.5 281.25
When unit is set to degree and "[Pr.83] Speed control 10
multiplier setting for degree axis" is valid
135 67.5 33.75 16.875
When unit setting is other than the above 1350 675 337.5 168.75