EasyManua.ls Logo

Mitsubishi Heavy Industries FDEN71VD User Manual

Mitsubishi Heavy Industries FDEN71VD
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
STANDARD INVERTER PACKAGED AIR-CONDITIONERS
V Multi System
(Split system, Air to air heat pump type)
Manual No. '10 PAC-DB-142
DATA BOOK
CEILING CASSETTE-4 WAY COMPACT TYPE
Single type
FDTC40ZIXVD
50ZIXVD
60ZIXVD
Triple type
FDTC140VNTVD
140VSTVD
Single type
FDT40ZIXVD
50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDT140VNTVD
140VSTVD
200VSTVD
Single type
FDEN40ZIXVD
50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDEN140VNTVD
140VSTVD
200VSTVD
Twin type
FDEN71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
CEILING CASSETTE-4 WAY TYPE
DUCT CONNECTED-LOW/MIDDLE STATIC PRESSURE TYPE
CEILING SUSPENDED TYPE
Single type
FDUM50ZIXVD
60ZIXVD
71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
140VNVD
140VSVD
Triple type
FDUM140VNTVD
140VSTVD
200VSTVD
DUCT CONNECTED-HIGH STATIC PRESSURE TYPE
Single type
FDU71VNVD
100VNVD
100VSVD
125VNVD
125VSVD
Twin type
FDUM100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
Twin type
FDT71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
140VNPVD
140VSPVD
200VSPVD
250VSPVD
Double Twin type
FDT200VSDVD
250VSDVD
Twin type
FDTC71VNPVD
100VNPVD
100VSPVD
125VNPVD
125VSPVD
Double Twin type
FDTC200VSDVD
FDTC250VSDVD
FDU140VNVD
140VSVD
200VSVD
250VSVD
(OUTDOOR UNIT)
FDC71VN
100VN
100VS
125VN
125VS
FDC140VN
140VS
200VS
250VS
(INDOOR UNIT)
FDT40VD
50VD
60VD
71VD
100VD
125VD
FDEN40VD
50VD
60VD
71VD
100VD
125VD
Ragarding the Service Manual please see the Manual No.’10 • PAC-SM-143.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDEN71VD and is the answer not in the manual?

Mitsubishi Heavy Industries FDEN71VD Specifications

General IconGeneral
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
RefrigerantR32
TypeSplit System Air Conditioner

Summary

STANDARD INVERTER PACKAGED AIR-CONDITIONERS

1.1 SPECIFICATIONS

Details technical specifications for various indoor unit types including capacity, power, and dimensions.

1.2 EXTERIOR DIMENSIONS

Provides exterior dimensions and installation space requirements for indoor and outdoor units.

1.3 ELECTRICAL WIRING

Illustrates electrical wiring diagrams and connection methods for indoor and outdoor units.

1.7 PIPING SYSTEM

Illustrates refrigerant piping diagrams for single, twin, triple, and double twin type systems.

1.8 RANGE OF USAGE & LIMITATIONS

Outlines operating temperature ranges, installation site limitations, and piping constraints for the air conditioning units.

1.9 SELECTION CHART

Crucial for choosing the right system.

1.9.1 Capacity tables

Presents capacity tables (TC, SHC, HC) for various indoor and outdoor unit combinations under different conditions.

1.9.3 Correction of cooling and heating capacity in relation to one way length of refrigerant piping

Details correction factors for capacity based on refrigerant piping length and diameter.

1.10 APPLICATION DATA

Practical installation guidance.

1.10.1 Installation of indoor unit

Provides detailed instructions and safety precautions for installing various indoor unit types.

1.10.3 Installation of outdoor unit

Covers installation procedures and safety precautions for outdoor units of different models.

1.10.4 Electric wiring work installation

Details electrical wiring procedures, safety precautions, and connection methods for the air conditioning system.

V MULTI SYSTEM

2.1 GENERAL INFORMATION

Provides general information about the V Multi system, including model reading and system combinations.

2.1.3 Table of system combinations

Lists valid combinations of outdoor units with indoor units and required branch pipe sets for V Multi systems.

2.2 SPECIFICATIONS

Product details.

(1) Indoor units

Specific indoor unit specs.

(a) Ceiling cassette-4way type (FDT)

Provides detailed specifications for FDT series indoor units, including operational data, dimensions, and electrical requirements.

(2) Outdoor units

Lists detailed specifications for outdoor units including power source, capacity, dimensions, and refrigerant details.

2.3 EXTERIOR DIMENSIONS

Details the exterior dimensions and installation space requirements for various indoor and outdoor units.

2.7 PIPING SYSTEM

Illustrates refrigerant piping diagrams for V Multi systems, showing connections for different unit types.

2.9 SELECTION CHART

Provides a chart for selecting appropriate V Multi systems based on capacity and unit combinations.

OPTION PARTS

3.1 WIRELESS KIT

Accessory installation.

3.1.1 FDTC Series (RCN-TC-24W-ER)

Details the installation and operation of the RCN-TC-24W-ER wireless remote controller for FDTC series.

3.1.3 FDEN Series (RCN-E1R)

Explains the installation and operation of the RCN-E1R wireless remote controller for FDEN series units.

3.2 SIMPLE WIRED REMOTE CONTROLLER (RCH-E3)

Details the names, functions, installation, and operation of the RCH-E3 wired remote controller.

3.3 FAN CONTROLLER KIT (U-FCRA)

Provides instructions for installing and wiring the U-FCRA fan controller kit for high static pressure ducts.

3.4 BASE HEATER KIT (CW-H-E)

Explains the installation procedure for the CW-H-E base heater kit for outdoor units in low-temperature environments.