Mitsubishi Heavy Industries FDK56KXZE1 User Manual

Mitsubishi Heavy Industries FDK56KXZE1
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL MANUAL
Manual No.'19 • KX-T-310D
Note:
(INDOOR UNIT)
VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS
Duct connected-High
static pressure type
compact type
Ceiling cassette-4 way type
FDT28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
112KXZE1
140KXZE1
160KXZE1
Wall mounted type
FDK15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
FDE36KXZE1
45KXZE1
56KXZE1
71KXZE1
112KXZE1
140KXZE1
Ceiling cassette-4 way
FDTC15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
Ceiling cassette-2 way type
FDTW28KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
Ceiling cassette-1 way type
FDTS45KXE6F
71KXE6F
Ceiling suspended type
FDU650FKXZE1
1100FKXZE1
1800FKXZE1
2400FKXZE1
Outdoor air processing unit
FDU45KXE6F
Duct connected (thin)-Low
static pressure type
FDUT71KXE6F-E
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
224KXZE1
280KXZE1
Duct connected-Low/Middle
static pressure type
FDUM22KXE6F
28KXE6F
36KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
(1) This document describes the indoor units with service code /F (with motion sensor system
function).
DRAFT

Questions and Answers:

Mitsubishi Heavy Industries FDK56KXZE1 Specifications

General IconGeneral
Cooling Capacity5.6 kW
Heating Capacity6.3 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Weight (Indoor Unit)10 kg
TypeAir Conditioner
Outdoor Unit Noise Level50 dB(A)

Summary

Specifications

Exterior Dimensions

Electrical Wiring

Ceiling Cassette-4 Way Type (FDT)

Electrical wiring diagram for FDT series 4-way ceiling cassette indoor units, showing PCB connections, power source, and wiring details.

Capacity Tables

Ceiling Cassette-4 Way Type (FDT)

Cooling and heating capacity tables for FDT series ceiling cassette indoor units, showing performance at various indoor/outdoor temperatures and airflows.

Ceiling Cassette-4 Way Compact Type (FDTC)

Capacity tables for FDTC series compact ceiling cassette indoor units, detailing cooling and heating performance across different temperature and airflow conditions.

Ceiling Cassette-2 Way Type (FDTW)

Capacity tables for FDTW series 2-way ceiling cassette indoor units, presenting cooling and heating performance data at various conditions.

Ceiling Cassette-1 Way Type (FDTS)

Capacity tables for FDTS series 1-way ceiling cassette indoor units, showing cooling and heating performance based on indoor/outdoor temperatures and airflow.

Duct Connected-High Static Pressure Type (FDU)

Capacity tables for FDU series high static pressure duct-connected units, detailing cooling and heating performance across different operating conditions.

Duct Connected Low/Middle Static Pressure Type (FDUM)

Capacity tables for FDUM series low/middle static pressure duct-connected units, providing cooling and heating performance data.

Outdoor Air Processing Unit (FDU-F)

Capacity tables for FDU-F series outdoor air processing units, providing cooling and heating performance data based on operating conditions.

Option Parts

Motion Sensor Kit

Details on the motion sensor kit as an optional part, including model numbers and general information.

Safety Precautions

Indoor Unit Motion Sensor Control

Explains the function of the motion sensor for indoor unit control, including power control and auto-off features.

Wireless Remote Control Settings

Instructions on how to set indoor functions, specifically for the motion sensor control using a wireless remote.

Wired Remote Control Settings

Instructions on how to set control modes for the motion sensor using wired remote controls like RC-EX3A or RC-E5.