TECHNICAL MANUAL
Manual No.'19 • KX-T-310D
Note:
(INDOOR UNIT)
VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS
Duct connected-High
static pressure type
compact type
Ceiling cassette-4 way type
FDT28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
112KXZE1
140KXZE1
160KXZE1
Wall mounted type
FDK15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
71KXZE1
90KXZE1
FDE36KXZE1
45KXZE1
56KXZE1
71KXZE1
112KXZE1
140KXZE1
Ceiling cassette-4 way
FDTC15KXZE1
22KXZE1
28KXZE1
36KXZE1
45KXZE1
56KXZE1
Ceiling cassette-2 way type
FDTW28KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
Ceiling cassette-1 way type
FDTS45KXE6F
71KXE6F
Ceiling suspended type
FDU650FKXZE1
1100FKXZE1
1800FKXZE1
2400FKXZE1
Outdoor air processing unit
FDU45KXE6F
Duct connected (thin)-Low
static pressure type
FDUT71KXE6F-E
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
224KXZE1
280KXZE1
Duct connected-Low/Middle
static pressure type
FDUM22KXE6F
28KXE6F
36KXE6F
45KXE6F
56KXE6F
71KXE6F
90KXE6F
112KXE6F
140KXE6F
160KXE6F
(1) This document describes the indoor units with service code /F (with motion sensor system
function).
DRAFT
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDT28KXZE1 and is the answer not in the manual?

Mitsubishi Heavy Industries FDT28KXZE1 Specifications

General IconGeneral
Cooling Capacity2.8 kW
Heating Capacity3.2 kW
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
RefrigerantR32
Seasonal Energy Efficiency Ratio (SEER)6.10

Summary

Specifications

Ceiling cassette-4 way type (FDT) Specifications

Provides detailed technical specifications for FDT series Ceiling cassette 4-way indoor units.

Ceiling cassette-4 way compact type (FDTC) Specifications

Details for FDTC15KXZE1, 22KXZE1, 28KXZE1, 36KXZE1, 45KXZE1, 56KXZE1 models including capacities, power, noise, and dimensions.

Ceiling cassette-2 way type (FDTW) Specifications

Details for FDTW28KXE6F, 45KXE6F, 56KXE6F, 71KXE6F models including capacities, power, noise, and dimensions.

Ceiling cassette-1 way type (FDTS) Specifications

Details for FDTS45KXE6F, 71KXE6F models including capacities, power, noise, and dimensions.

Duct connected-High static pressure type (FDU) Specifications

Details for FDU45KXE6F, 56KXE6F, 71KXE6F, 90KXE6F models including capacities, power, noise, and dimensions.

Duct connected-Low/Middle static pressure type (FDUM) Specifications

Details for FDUM22KXE6F, 28KXE6F, 36KXE6F, 45KXE6F, 56KXE6F models including capacities, power, noise, and dimensions.

Duct connected (thin)-Low static pressure type (FDUT) Specifications

Details for FDUT71KXE6F-E model including capacities, power, noise, and dimensions.

Wall mounted type (FDK) Specifications

Details for FDK15KXZE1, 22KXZE1, 28KXZE1, 36KXZE1, 45KXZE1, 56KXZE1 models including capacities, power, noise, and dimensions.

Ceiling suspended type (FDE) Specifications

Details for FDE36KXZE1, 45KXZE1, 56KXZE1, 71KXZE1 models including capacities, power, noise, and dimensions.

Outdoor air processing unit (FDU-F) Specifications

Details for FDU650FKXZE1, 1100FKXZE1, 1800FKXZE1, 2400FKXZE1 models including capacities, power, noise, and dimensions.

Exterior Dimensions

Indoor Unit Exterior Dimensions

Provides dimensional drawings for various indoor unit types like Ceiling cassette, Duct connected, Wall mounted, and Suspended types.

Remote control (Option parts) Exterior Dimensions

Exterior dimensions for wired and wireless remote controls.

Electrical Wiring Diagrams

Ceiling cassette-4 way type (FDT) Wiring Diagram

Detailed electrical wiring diagram for FDT series indoor units, showing PCB connections, motors, and sensors.

Duct connected-High static pressure type (FDU) Wiring Diagram

Electrical wiring diagram for FDU series indoor units, detailing connections to PCB, motors, and sensors.

Outdoor air processing unit (FDU-F) Wiring Diagram

Electrical wiring diagram for FDU-F series outdoor units, showing PCB connections, motors, and sensors.

Noise Level Data

Ceiling cassette-4 way (FDT) Noise Levels

Presents sound pressure and power level data in octave bands for FDT series ceiling cassette indoor units.

Duct connected-High static pressure type (FDU) Noise Levels

Noise level data for FDU series Duct connected High static pressure units across different speed settings.

Wall mounted type (FDK) Noise Levels

Noise level data for FDK series Wall mounted indoor units for cooling and heating modes.

Capacity Tables

Ceiling cassette-4 way type (FDT) Capacity Tables

Cooling and heating capacity data for FDT series models across various indoor and outdoor air temperatures.

Duct connected-High static pressure type (FDU) Capacity Tables

Cooling and heating capacity data for FDU series models across various indoor and outdoor air temperatures.

Ceiling suspended type (FDE) Capacity Tables

Cooling and heating capacity data for FDE series models across various indoor and outdoor air temperatures.

Option Parts

Motion Sensor Kit Installation

Installation instructions and cautions for the motion sensor kit (LB-T-5W-E) for FDT series indoor units.