EasyManua.ls Logo

Mitsubishi Heavy Industries FDTC50V User Manual

Mitsubishi Heavy Industries FDTC50V
396 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Manual No. '08PAC-T-118
TECHNI CAL M ANUAL
Collection data
PACKAGED AIR-CONDITIONER
MULTI-TYPE (V-MULTI)
PACKAGED AIR-CONDITIONER
(Split system, Air to air heat pump type)
CEILING CASSETTE-4 WAY COMPACT
(600×600mm)
-TYPE
CEILING CASSETTE-4 WAY TYPE
CEILING SUSPENDED TYPE
FDTC40ZHXV
50ZHXV
FDTC71VNPV
100VNPV
100VSPV
FDEN40ZHXV
50ZHXV
60ZHXV
71VNV
100VNV
100VSV
125VNV
125VSV
140VNV
140VSV
FDEN71VNPV
100VNPV
100VSPV
125VNPV
125VSPV
140VNPV
140VSPV
200VSPV
140VSTV
200VSTV
250VSPV
FDEN140VNTV
140VSTV
200VSTV
FDUM140VNTV
FDUM50ZHXV
60ZHXV
71VNV
100VNV
100VSV
125VNV
125VSV
140VNV
140VSV
FDU71VNV
100VNV
100VSV
125VNV
125VSV
140VNV
140VSV
200VSV
250VSV
FDUM100VNPV
100VSPV
125VNPV
125VSPV
140VNPV
140VSPV
200VSPV
250VSPV
FDT40ZHXV
50ZHXV
60ZHXV
71VNV
100VNV
100VSV
125VNV
125VSV
FDC71VN
100VN
100VS
125VN
125VS
140VN
140VS
200VS
250VS
FDTC40V
50V
FDT71VNPV
100VNPV
100VSPV
125VNPV
125VSPV
140VNPV
140VSPV
FDT140VNTV
FDT200VSDV
FDT40V
50V
60V
71V
100V
125V
FDEN40V
50V
60V
71V
100V
125V
FDUM50V
60V
71V
100V
125V
(OUTDOOR UNIT) (INDOOR UNIT)
DUCT CONNECTED-MIDDLE STATIC PRESSURE- TYPE
DUCT CONNECTED-HIGH STATIC PRESSURE- TYPE
140VNV
140VSV
FDTC140VNTV
140VSTV
200VSPV
250VSPV
140VSTV
200VSTV
250VSDV
updated July 08, 2011
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries FDTC50V and is the answer not in the manual?

Mitsubishi Heavy Industries FDTC50V Specifications

General IconGeneral
Cooling Capacity5.0 kW
Heating Capacity5.6 kW
Power Source220-240V, 50Hz
RefrigerantR32
Energy Efficiency Ratio (Cooling)3.21
Energy Efficiency Ratio (Heating)3.61
Noise Level (Outdoor)50 dB(A)

Summary

1. PACKAGED AIR-CONDITIONER

1.1 GENERAL INFORMATION

Overview of features, COP, energy labeling, and operational characteristics.

1.2 SELECTION DATA

Detailed specifications for various indoor and outdoor unit types, including dimensions and electrical data.

1.3 ELECTRICAL WIRING

Explanation of wiring diagrams for indoor and outdoor units, covering connection details and color codes.

1.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER

Description of remote controller functions, operation modes, and control logic for various states.

1.5 APPLICATION DATA

Guidelines for installation, piping requirements, and system limitations for proper setup.

1.6 MAINTENANCE DATA

Procedures for servicing, troubleshooting common issues, and diagnosing faults.

2. MULTI-TYPE (V MULTI) PACKAGED AIR-CONDITIONER

2.1 GENERAL INFORMATION

Features flexibility, COP, operation range, and installation benefits of the V-MULTI series.

2.2 SELECTION DATA

Specifications for indoor/outdoor units, capacity, dimensions, and refrigerant piping.

2.3 ELECTRICAL WIRING

Wiring diagrams for unit types, showing power, control, and signal line connections.

2.4 OUTLINE OF OPERATION CONTROL BY MICROCOMPUTER

Explains wired/wireless remote controller functions and troubleshooting.

2.5 APPLICATION DATE

Details system combinations, pipe set specifications, and installation guidelines.

2.6 MAINTENANCE DATE

Servicing procedures, troubleshooting, and component inspection for maintenance.

3. WIRELES KIT (OPTIONAL PARTS)

3.1 FDT SERIES (RCN-T-36W-E)

Instructions for installing the wireless receiver and setting up the FDT series remote controller.

3.2 FDTC SERIES (RCN-TC-24W-ER)

Details on installing the wireless receiver for FDTC series, including preparation and wiring.

3.3 EXCEPT FOR FDT AND FDTC SERIES (RCN-KIT3-E)

Installation instructions for wireless kits not specific to FDT or FDTC series.

Related product manuals