Cooling Capacity | 7.1 kW |
---|---|
Heating Capacity | 8.0 kW |
Refrigerant | R32 |
Power Supply | 220-240V, 50Hz |
Outdoor Unit Noise Level | 50 dB |
Detailed specifications for Ceiling Cassette-4 Way Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Ceiling Cassette-4 Way Compact Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Ceiling Cassette-2 Way Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Ceiling Cassette-1 Way Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Duct Connected-High Static Pressure Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Duct Connected-Low/Middle Static Pressure Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Duct Connected (thin)-Low Static Pressure Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Wall Mounted Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Ceiling Suspended Type indoor units, covering capacities, power, noise, and dimensions.
Detailed specifications for Outdoor Air Processing Unit indoor units, covering capacities, power, noise, and dimensions.
Illustrates the exterior dimensions for various indoor unit types, including ceiling cassette and duct-connected models.
Provides detailed exterior dimensions and installation layout for FDT series ceiling cassette indoor units.
Provides detailed exterior dimensions and installation layout for FDTC series ceiling cassette indoor units.
Provides detailed exterior dimensions and installation layout for FDTW series ceiling cassette indoor units.
Provides detailed exterior dimensions and installation layout for FDTS series ceiling cassette indoor units.
Provides detailed exterior dimensions and installation layout for FDU series high static pressure duct units.
Provides detailed exterior dimensions and installation layout for FDUM series low/middle static pressure duct units.
Provides detailed exterior dimensions and installation layout for FDUT series thin duct units.
Provides detailed exterior dimensions and installation layout for FDK series wall mounted indoor units.
Provides detailed exterior dimensions and installation layout for FDE series ceiling suspended indoor units.
Provides detailed exterior dimensions and installation layout for FDU-F outdoor air processing units.
Electrical wiring diagram for FDT series ceiling cassette indoor units, detailing component connections.
Electrical wiring diagram for FDTC series ceiling cassette indoor units, detailing component connections.
Electrical wiring diagram for FDTW series ceiling cassette indoor units, detailing component connections.
Electrical wiring diagram for FDTS series ceiling cassette indoor units, detailing component connections.
Electrical wiring diagram for FDU series high static pressure duct units, detailing component connections.
Electrical wiring diagram for FDUM series low/middle static pressure duct units, detailing component connections.
Electrical wiring diagram for FDUT series thin duct units, detailing component connections.
Electrical wiring diagram for FDK series wall mounted indoor units, detailing component connections.
Electrical wiring diagram for FDE series ceiling suspended indoor units, detailing component connections.
Noise level data for FDT series ceiling cassette units across various octave bands and speed settings.
Noise level data for FDTC series ceiling cassette units across various octave bands and speed settings.
Noise level data for FDTW series ceiling cassette units across various octave bands and speed settings.
Noise level data for FDTS series ceiling cassette units across various octave bands and speed settings.
Noise level data for FDU series high static pressure duct units across various octave bands and speed settings.
Noise level data for FDUM series low/middle static pressure duct units across various octave bands and speed settings.
Noise level data for FDUT series thin duct units across various octave bands and speed settings.
Noise level data for FDK series wall mounted units across various octave bands and speed settings.
Noise level data for FDE series ceiling suspended units across various octave bands and speed settings.
Noise level data for FDU-F outdoor air processing units across various octave bands and speed settings.
Cooling and heating capacity tables for FDT series ceiling cassette indoor units under various conditions.
Cooling and heating capacity tables for FDTC series ceiling cassette indoor units under various conditions.
Cooling and heating capacity tables for FDTW series ceiling cassette indoor units under various conditions.
Cooling and heating capacity tables for FDTS series ceiling cassette indoor units under various conditions.
Cooling and heating capacity tables for FDU series high static pressure duct units under various conditions.
Cooling and heating capacity tables for FDUM series low/middle static pressure duct units under various conditions.
Cooling and heating capacity tables for FDUT series thin duct units under various conditions.
Cooling and heating capacity tables for FDK series wall mounted units under various conditions.
Cooling and heating capacity tables for FDE series ceiling suspended units under various conditions.
Cooling and heating capacity tables for FDU-F outdoor air processing units under various conditions.
Details on the motion sensor kit, including installation, wiring, and setting procedures for indoor units.
Detailed steps for physically installing the motion sensor, including options for different unit types and locations.
Instructions for connecting the motion sensor wiring to the indoor unit's control box PCB.
Guidance on configuring the motion sensor functionality via wired or wireless remote controls.