−17−−16−
11
Acknowledge screen for the completion of setting is displayed.
To change other ap motion ranges, tap the Yes button. (
3 )
To terminate the setting, tap the No button. The display returns to the TOP screen.
10
Acknowledge screen for the ap
motion range is displayed.
Flap
2
setting is completed
No
Tap [No] to return to top screen.
Yes
Setting the range of flap
2
motion is complete.
Do you want to set other aps?
Flap
2
Swing range
Back
Tap [Back] for resetting.
Yes
Do you want to set the
range of ap motion?
If yes, tap [Yes].
Advice
When the unit is installed within 50 cm from a wall, it is recommended that you change the range
of the left/right ap motion as follows:
When installed at the right end of the wall
Left/right ap motion range
1
to
4
When installed at the left end of the wall
Left/right ap motion range
2
to
5
Installed at
the left end
Installed at
the right end
Anti draft setting (for using panel with anti draft)
1
Tap the Menu button on the TOP screen and select Useful functions
Anti draft setting .
The Anti draft setting menu is displayed.
Depending on how the Permission/Prohibition setting (
Refer to user’s manual.) is set, the administrator password input screen
may be displayed.
1
When two or more IUs are
connected to the R/C, a list of IUs is
displayed. Tap the IU to be set.
You can set ON/OFF (operation/stop) of the anti draft function and can also enable/disable the motion of panel with anti draft for each blow outlet for each operation mode.
When the R/C is set as the sub R/C, the anti draft setting cannot be set.
IU select
Next Back
Select an IU address.
2
Select the blow outlet number to set anti draft.
The ap at blow outlet No.
1
will keep moving while the blow outlet selection screen is
displayed. Select the ap based on this gure. When you have selected the blow outlet,
the ap with the number you selected will move. The gure displayed on the screen shows
the installed unit viewed from the oor side.
This operation will not be performed when anti draft setting is set during operation.
Advice
You can set all blow outlets at once by tapping the
Bat.set.
button.
An icon that indicates the operation mode is shown on each blow outlet button.
When the anti draft setting is enabled, the icon color will be reversed (for example,
in the left gure, blow outlets which have the anti draft setting enabled during
cooling are numbers
1
,
3
, and
4
).
3
Select enable/disable for each
operation mode.
After you make the selection, tap
the
Set button.
The display returns to the blow
outlet selection screen.
Anti draft setting mode setting
Set Back
Select the item.
DisableDry
DisableFan
DisableHeating
DisableCooling
Enable
Enable
Enable
Enable
2
Tap a desired item.
1
Details ..................... You can set Enable or Disable for anti draft
motion performed at each blow outlet in each
operation mode. (
16)
2
ON/OFF setting ....... You can set ON/OFF (operation/stop) of anti draft
function for the enabled blow outlet set in
1
Details.
(
16)
Details
1
The indoor unit No. and the ON/OFF state of each anti draft function are displayed to allow ON/OFF setting of the anti draft. Anti
draft is turned OFF by tapping ON and turned ON by tapping OFF.
When two or more indoor units equipped with anti draft function are connected to the R/C, the two or more indoor units are
displayed.
All of the connected indoor units that are equipped with anti draft function are turned OFF by pressing the
All OFF button.
All of the connected indoor units that are equipped with anti draft function are turned ON by pressing the All ON button.
ON/OFF setting
№④
№②
№① №③
配管側
ドレンホース側
ルーバ№
[FDTの場合]
Pipe side
Control box
Drain hose side
Blow outlet No.
[For FDT]
№④
№②
№③
配管側レンホース側
ルーバ№
FDTCの場合
№①
Pipe sideDrain hose side
Louver No.
[For FDTC]
If the humidity around the IU is high even after anti draft is set to ON, the anti draft may stop in order to prevent condensation forming on the IU. In that case,
the message "During condensation prevention control." will be displayed.
When the humidity drops, the anti draft will be reactivated.
Advice