−23−−22−
1
On the TOP screen, set the desired operation mode, set temp, fan speed, and ap direction.
Tap the Menu button on the TOP screen and select Useful functions
Favorite setting .
The administrator password input screen is displayed.
Enter the administrator password.
You cannot register the favorite settings during high power and energy-saving operations.
2
The save location selection screen for favorite settings is displayed.
Select the save location.
If there is any data that was previously saved, that data will be overwritten.
Registering favorite settings
Operation mode, set temp, fan speed, fan direction can be registered as Favorite set 1 and Favorite set 2.
Allocating these settings to the F1
and F2 switches allows you to perform operations with these registered settings with a single tap of the button.
Refer to the F1/F2 function setting on how to set the F1
and F2 switches.
Favorite set 2
Favorite set 1
Favorite setting
Back
Saving current state of operation
Saving where?
1
When you press the F1 ( F2 ) switch, the operation mode, set temp, fan speed, flap direction registered to Favorite set 1 or
Favorite set 2 will be enabled.
Operation will start even if you press the
F1
(
F2
) switch while the unit is stopped.
You can change the operation mode, set temp, fan speed, ap direction after the operation has started with the favorite setting operation.
Following power on, the unit starts to operate initially with the following settings for both Favorite set 1 and Favorite set 2.
Operation mode ...Cooling
Set temp ...28°C
Fan speed ...3-speed
Flap direction ...Position 2
When an FDK with a left/right ap is connected
Left/right ap direction ...Center
3D AUTO ...Disabled
When Change set temp, Change operation mode, Change ap direction, Change fan speed are restricted by the Permission/Prohibition setting,
restricted items will not be reected to the favorite setting operation.
Favorite setting operation
You can start an operation with the operation mode, set temp, fan speed, flap direction registered to Favorite set 1 and Favorite set 2.
Settings for the operation mode, set temp, fan speed, flap direction can be registered from Favorite setting on the menu.
Favorite setting operation must be set to the F1
or F2 switch.
Menu
Direction
Cooling
16:32
(Mon)
F1: Favorite set 1 F2: Favorite set 2
Timer
In operation for running.
Set temp
1
Tap the Menu button on the TOP screen and select Useful functions
Silent mode control .
The administrator password input screen is displayed.
Enter the administrator password.
2
The Silent mode control (Start/End) screen is displayed.
Tap the
Start button to start the silent mode control.
To terminate the silent mode control, tap the
End button.
3
During silent mode control, “Outdoor unit silent mode control ON” will be displayed on the message display.
Silent mode control will not be disabled even if you press the
Run/Stop
switch.
When the sub R/C is set, the silent mode control cannot be used.
During silent mode control, operation with maximum capacity is not allowed.
Silent mode control
The OU is controlled with priority on quietness. You can start/stop the silent mode control.
[Starting control with
Menu
button]
PJZ012A231_EN.indd 23PJZ012A231_EN.indd 23 2023/7/24 10:49:422023/7/24 10:49:42