−27−−26−
1
Tap the Menu button on the TOP screen and select Useful functions
Control mode & Eco level .
If no OU equipped with control mode & eco level function is connected, Control mode & Eco level will not be displayed.
2
When two or more IUs are connected to the R/C, a list of IUs is displayed. Tap the IU to be set.
3
Tap a desired item.
1
Cool, Dry ....You can set the control mode for Cooling or Dry.
2
Heating.......You can set the control mode for Heating.
The rest of the procedure is the same for both items.
4
Select the control mode.
1
Saving mode ...... Most energy saving mode.
Suitable for low cooling/heating demand in the building.
2
VTCC+ mode ..... Most balanced mode between capacity control and energy saving.
Suitable for cooling/heating demand varies among the room in the building.
3
Std mode............ Capacity is maximised.
Suitable for high cooling/heating demand in the building.
5
Select the eco level.
Eco level: U-High > High > Mid > Low
The eco level can be set only when ”Saving mode” or ”VTCC+ mode” is selected in control mode.
Control mode & Eco level
Automatically controls the capacity depending on the R/C set temperature and the indoor temperature, which enables the energy-saving operation without sacricing comfort.
When the R/C is set as the sub R/C, the control mode & eco level cannot be set.
IU select
Next Back
Select an IU address.
PJZ012A231_EN.indd 27PJZ012A231_EN.indd 27 2023/7/24 10:49:432023/7/24 10:49:43