16
1
Push the F1 ( F2 )switch to start the energy-saving operation.
Operation will start even if you press the
F1
(
F2
) switch while the unit is
stopped.
Energy-saving operation is only allowed when Heating, Cooling or Auto is
selected for the operation mode.
Message “In operation for energy-saving.” is displayed on the screen
during the energy-saving operation. Set temp is xed at “28.0°C” in
the cooling operation or “22.0°C” in the heating operation. Set temp
shows “- -°C” in the automatic operation mode.
Set temp cannot be changed during the energy-saving operation. If it is
attempted, a message “Invalid request” is displayed on the screen.
2
Energy-saving operation is terminated when you perform the
following.
When you terminate through a Run/Stop
operation
When you change the operation mode
When you terminate the energy-saving operation with the F1
( F2 ) switch
Energy-saving operation
Use this operation to save energy. Set temp is xed at 28°C in the cooling operation or 22°C in the heating operation.
Since the capacity is controlled automatically based on the outdoor temperature, energy can be saved without losing
comfort.
Energy-saving operation must be set to the F1
or F2 switch (
page 66)
Energy-saving operation is set to the F2
switch as the factory setting.
Menu
Direction
Auto
16:04
(Mon)
F1: High power F2: Energy-saving
Timer
In operation for energy-saving.