EasyManua.ls Logo

Mitsubishi Heavy Industries RLA502A701L User Manual

Mitsubishi Heavy Industries RLA502A701L
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE
SUPPORT
HANDBOOK
www.dwgeire.ie

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries RLA502A701L and is the answer not in the manual?

Mitsubishi Heavy Industries RLA502A701L Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelRLA502A701L
CategoryAir Conditioner
LanguageEnglish

Summary

MHI e-service App

SRK Remote Control Guide

Remote Control Button Functions

Explains the function of each button on the remote control.

SRK Remote Control Functions

RC-E5 Remote Control Layout

RC-E5 Operation Data

RC-EX1 & EX1A Remote Control Layout

RC-EX3 Remote Control Layout

RC-EX Operation Data

Compressor Protection Status Details

Lists and explains 33 compressor protection status codes.

Master / Slave and Group Settings

System Configuration and Compatibility

Explains system types and SC-BIKN-E interface compatibility.

Refrigerant Piping Information

Current RAC & PAC Models

Provides refrigerant piping specs for current RAC and PAC models.

SCM Multi Split Systems

Details refrigerant piping specs for SCM multi-split systems.

Refrigerant Piping Information - Historic Models

RAC Fault Codes

Inverter RAC Unit Fault Codes

Lists fault codes and causes for inverter RAC indoor and outdoor units.

RAC Multisplit Fault Codes

Current & Previous Multisplit Models

Fault codes and causes for current/previous multisplit units.

RAC Multisplit Fault Codes - Historic Models

PAC Self-Diagnosis Information

Inverter PAC Indoor Unit Diagnosis

Self-diagnosis codes and causes for inverter PAC indoor units.

Inverter PAC Outdoor Unit Diagnosis

Self-diagnosis codes and causes for inverter PAC outdoor units.

PAC Self-Diagnosis Information

Inverter PAC Outdoor Unit Diagnosis

Self-diagnosis codes and causes for inverter PAC outdoor units.

KX Self-Diagnosis Information

Inverter KX Unit Self-Diagnosis

Self-diagnosis error codes and probable causes for Inverter KX units.

Compressor Winding Resistance Test

Procedure to test compressor winding resistances and diagnosis.

Test Procedure – Inverter Checker Compatibility

Type A SRC & KX4 Outdoor Units

Compatibility and testing procedure for Type A SRC & KX4 units with inverter checker.

Test Procedure – Using an Inverter Checker

Type B & C Outdoor Units

Testing procedure for Type B and C units using an inverter checker.

Troubleshooting Refrigeration System

Service Mode Procedures

Service Data Recording and Interpretation

Details how error and stop codes are recorded in service mode.

Service Mode Error & Stop Code Tables (SRK Models)

SRK ZD-S, ZF-S, ZG-S Codes

Error and stop codes for SRK ZD-S, ZF-S, ZG-S models.

SRK ZFX-S, ZGX-S Codes

Error and stop codes for SRK ZFX-S, ZGX-S models.

SRK ZE-S, ZE-S1 Codes

Error and stop codes for SRK ZE-S, ZE-S1 models.

PFD Box Replacement

CNT 6 Wire Adapter Kit Installation

Changing Operation via CNT Connector

Related product manuals