Manual No. '06 • SCM-T-052
INVERTER MULTI-SPLIT SYSTEM
ROOM AIR-CONDITIONER
(Air to air heat pump type)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SCM40ZF-S and is the answer not in the manual?

Mitsubishi Heavy Industries SCM40ZF-S Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSCM40ZF-S
CategoryAir Conditioner
LanguageEnglish

Summary

GENERAL INFORMATION

Specific features

Details product features like piping length and unit capacities.

How to read the model name

Explains the meaning of characters in the model name.

SELECTION DATA

Specifications

Lists technical specifications for indoor and outdoor units.

Range of usage & limitations

Outlines operating conditions and limitations for the system.

Exterior dimensions

Provides dimensional drawings and data for indoor and outdoor units.

Piping system

Illustrates the refrigerant piping layout for different models.

Selection chart

Shows correction factors for capacity based on temperatures.

ELECTRICAL DATA

Electrical wiring

Details the wiring diagrams for indoor and outdoor units.

OPERATION CONTROL

Operation control function by remote control switch

Explains how to control the unit's operation using the remote control.

Wired remote control features

Details the features and operation of the wired remote control.

Unit indication section

Explains the meaning of indicator lights on the indoor unit.

APPLICATION DATA & INSTALLATION

SAFETY PRECAUTIONS

Important safety precautions to follow during installation.

Indoor Unit Installation

Provides instructions and cautions for installing indoor units.

Outdoor Unit Installation

Outlines the selection and installation criteria for outdoor units.

Electrical Wiring and Piping

Covers electrical wiring, refrigerant piping, and connections.

Test Run and Handling

Guides on performing test runs and handling the unit after installation.

Optional Parts Installation (Ducted Type)

Details the installation of ducted type optional parts.

MAINTENANCE DATA

Trouble shooting

Provides a flowchart for troubleshooting common issues.

Indication of self diagnosis

Explains the self-diagnosis indications, causes, and conditions.

Component Inspection Procedures

Detailed inspection steps for sensors, motors, and PCBs.

Specific Fault Diagnosis

Troubleshooting procedures for specific faults like current cut, rotor lock, etc.

Servicing Procedures

Outlines procedures for servicing, including evacuation and refrigerant charging.

R410A REFRIGERANT SYSTEMS

R410A Refrigerant Overview

Introduces R410A refrigerant, its characteristics, and safety during installation/servicing.

Refrigerant Piping Installation

Details on copper pipes, joints, processing, flux, brazing, and tools for R410A.

New Installation and Refrigerant Handling

Procedures for new installation, refrigerant charging, recovery, and recharging.

Removal and Replacement

Steps for removing, installing, replacing units, and retrofitting.