EasyManuals Logo

Mitsubishi Heavy Industries SCM60ZJ-S User Manual

Mitsubishi Heavy Industries SCM60ZJ-S
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #111 background imageLoading...
Page #111 background image
-
110
-
'10 • SCM-SM-094
Error code
Remote controller:
LED Green Red
Content
Indoor
Keeps flashing
Stays OFF
E51
Power transistor anomaly
Outdoor
1
time flash
Error code
Remote controller: E51
LED Green Red
Indoor
Content
Power transistor error
Keeps flashing
Stays Off
1. Applicable model
5. Troubleshooting
All models
Diagnosis Countermeasure
2. Error detection method
3.
Condition of Error displayed
4. Presumable cause
Note:
If the power transistor primary
current exceeds the setting value
for 3 seconds, the compressor
stops.
Power transistor primary current
• Faulty outdoor main PCB
• Dust on outdoor main PCB
• Blown F2 fuse
NO
NO
Check soldered
surfaces on the outdoor main PCB for
foreign matter like dust,
fouling,etc.
Isn’t F2 fuse
(250V, 20A)blown?
Remove foreign matter
like dust, fouling, etc.
Replace fuse.
Defective outdoor main
PCBªReplace.
YES

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Heavy Industries SCM60ZJ-S and is the answer not in the manual?

Mitsubishi Heavy Industries SCM60ZJ-S Specifications

General IconGeneral
BrandMitsubishi Heavy Industries
ModelSCM60ZJ-S
CategoryAir Conditioner
LanguageEnglish

Related product manuals